Appendix C: Grounding and RF protection
Alternative grounding for fiberglass hulls
163
CCCC
Gr
ounding
and
RF
C.7 Alternative grounding for fiberglass hulls
C.7.1 Grounding the terminal
The terminal must be grounded with the short antenna cable and a grounding
kit. Further, the terminal must be grounded at its grounding stud in order to
ensure a proper grounding if the short antenna cable is disconnected.
The ground connection must be established at a dedicated RF ground (either
capacitive or electrical coupled). Bear in mind that the antenna ground
connection is to be made at the
same electrical ground potential
as the
terminal (see
C.7.2 Grounding the antenna
If the mounting base of the antenna is electrically connected to any other
ground potential than the terminal (e.g. Lightning Ground), the antenna must
be isolated at its mounting bolts by means of shoulder bushings and washers
- see page 169.
However, a ground connection must be established via one of the mounting
bolts using a separate ground cable. The ground cable must be routed parallel
and in close proximity to the shielded coax cable hence connecting the
antenna to the terminal Grounding kit. A tinned heavy gauge wire (min. 6
mm2) can be used for this purpose - see page 164.
Summary of Contents for FB250
Page 13: ...Table of contents xii ...
Page 77: ...Chapter 3 Connecting power 64 Connecting power ...
Page 105: ...Chapter 5 Starting up the system 92 Operating the system ...
Page 129: ...Chapter 6 Service and repair 116 Replacing modules in 34 3052B antenna ...
Page 139: ...Chapter 7 Troubleshooting 126 Logging of events ...
Page 165: ...Appendix B Technical specifications 152 TracPhone terminal ...
Page 197: ...Glossary 184 ...