Chapter 6: Service and repair
Replacing modules in 34-3052B antenna
115
666
Ser
vic
e and r
ep
a
ir
Mounting the ATM module
To mount the new ATM, repeat the above procedure in reverse:
1. Slide the sensor PCB through the slot.
2. Fit the six Hex screws on the ATM. Fasten the screws with 1.2 Nm torque.
3. Reconnect the plugs. Make sure the plugs are fitted properly. You should
hear a click when the plug is fully inserted.
4. Turn the sensor PCB so that the cable can be positioned naturally as shown
in the image below.
5. Gently lift the two cable holders (b and c) and fit the cable in them and
mount the three screws with torque 1.0 Nm.
6. Refit the two cable ties (a and b), and make sure the antenna can move
freely, without the sensor PCB cable obstructing the movement.
a
b
c
d