3,000 Cycles
Inspect
Inspect feed belts for proper tension or damage.
Inspect
Inspect screw drop tubes for kinks, cracks or wear from rubbing. Ensure tube
clamps are tight.
Inspect
Inspect all photo eyes secure and tight.
Inspect
Inspect
all
limit
switch
arms
for
tightness
or
breaks
Inspect
Inspect split shells and screw receivers on six shooters for cracks or breaks.
Replace if broken.
Inspect
Inspect all airlines for kinks or rubbing.
Lubricate
Refill all lubricators. Replace fluid if milky or discolored. Use ab ISO 32 stan-
dard hydraulic oil (KVAL PN:SYS-LUBEG).
Lubricate
Grease ball screw bearings (if applicable).
Clean
Clean all bearing shafts with clean, dry cloth.
12,000 Cycles
Inspect
Inspect chains for proper tension or damage
Inspect
Inspect all air cylinders for air leaks. Replace if seal is leaking
Inspect
Inspect
hydraulic
lines
for
loose
fittings,
leaks
and
cracks.
Inspect
Inspect
ball
rail
shafts
for
pitting
or
abrasions.
Lubricate
Clean
and
lubricate
all
slides
and
cylinder
rods
with
dry
silicone
spray
Lubricate
Lubricate
all
bearing
shafts
with
silicone
and
clean
rag.
Clean
Clean inside hopper with WD-40 and a 3M Scotchbrite
®
pad. Wipe dry with a
clean dry rag
72,000 Cycles
Inspect
Inspect all nuts and bolts for tightnesses Tighten is necessary.
Inspect
Check
that
there
is
a
smooth
transition
with
a
door
feeding
into
and
out
of
machine.
Back-up
Backup
computer
software.
Clean
Wash
filter
and
lubricator
bowls
with
soapy
water.
Maintenance Schedule
5-3
KVAL 994-X Operation/Service Manual
Summary of Contents for 994-X
Page 4: ...KVAL 994 X Operation Service Manual ...
Page 31: ...Safety Sign Off Sheet 1 21 KVAL 994 X Operation Service Manual ...
Page 32: ...Safety Sign Off Sheet KVAL 994 X Operation Service Manual 1 22 ...
Page 110: ...Calibration of the Back Section KVAL 994 X Operation Service Manual 3 22 ...
Page 114: ...System IT Administration KVAL 994 X Operation Service Manual 4 4 ...
Page 144: ...Collet Torque Values KVAL 994 X Operation Service Manual 5 30 ...
Page 180: ...Symptoms and Possible Causes KVAL 994 X Operation Service Manual 6 36 ...
Page 185: ......
Page 186: ......
Page 187: ......