AC/DC TRMS

DIGITAL CLAMPMETER

MODEL - KM 035

I. SAFETY :

The  accompanied  test  probe  assembly  meets  UL/IEC/EN61010-
031  Ed.  2.0  to  the  same  meter  ratings  or  better.    IEC  61010-031 

requires exposed conductive test probe tips to be 

 4mm for CAT 

III & CAT IV ratings.  Refer to the category markings on your probe 
assemblies as well as on the add-on accessories (like detachable 
Caps or Alligator Clips), if any, for applicable rating changes.

The meter meets UL / IEC / EN61010-1 Ed. 3.0, CAN / CSA C22.2 
No.  61010-1Ed.3.0,  UL/IEC/EN61010-2-032  Ed.3.0,  UL/IEC/
EN61010-2-033  Ed.  1.0  to  measurement  CAT-III  600V  and 
CAT-IV 300V, AC & DC.

TERMS IN THIS MANUAL :

WARNING

Identifies  conditions  and  actions  that  could result in 
serious injury or even death to the user.

CAUTION

Identifies   conditions  and  actions   that  could  cause
damage or malfunction in the instrument.

01

WARNING :

This  manual  contains  information  and  warnings  that  must  be 

followed for operating the meter safely and maintaining the meter in 

a  safe  operating  condition.    If  the  meter  is  used  in  a  manner  not 

specified by the manufacturer, the protection provided by the meter 

may be impaired.

Observe  proper  safety  precautions  when  working  with  voltages 

above 30 Vrms, 42.4 Vpeak or 60VDC.  These voltage levels pose a 

potential  shock  hazard  to  the  user.    Do  not  expose  this  product  to

rain or moisture.  The meter is intended only for indoor use.

Summary of Contents for KM 035

Page 1: ...or Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproo...

Page 2: ...nd CAT IV 300V AC DC TERMS IN THIS MANUAL WARNING Identifies conditions and actions that could result in serious injury or even death to the user CAUTION Identifies conditions and actions that could c...

Page 3: ...lled before the main fuse or circuit breaker in the building installation 03 II CENELEC Directives The instruments conform to CENELEC Low voltage directive 2014 35 EU Electromagnetic compatibility dir...

Page 4: ...s APO Consumption typical 5 A Dimension 188 L x 66 W x 32 H mm Weight approx 202 gms 05 SAFETY Safety Certified per IEC UL CSA_C22 2_ EN standards 61010 1 Ed 3 0 61010 2 032 Ed 3 0 61010 2 033 Ed 1 0...

Page 5: ...readings if any Range 1 2 Accuracy Resolution 2 0 rdg 5dgts 0 1 A 600 0 A 07 600 0 V 1 0 rdg 5dgts DC VOLTAGE Accuracy Resolution Range 0 1 V Input Impedance 10M 100pF nominal AC VOLTAGE with Digital...

Page 6: ...V 500V 160V 80V 20V 140V 320V 80V 560V 09 VI PRODUCT DESCRIPTION This manual uses only representative model s for illustrations Please refer specification details for function availability to this mod...

Page 7: ...of only one single pole of a circuit for load current measurements Make sure the jaws are completely closed or else it will introduce measure ment errors Enclosing conductors of more than one pole of...

Page 8: ...AT IV A Hz COM 300V CAT IV 28 0 600V CAT III SELECT V V CREST REC EF A A 1 Press SELECT button momentarily to select DCA function 13 OFF MAX 600A 600V CAT III 300V CAT IV A Hz COM 300V CAT IV 32 600V...

Page 9: ...ing further drops below 0 100V the meter gives a continuous beep tone together with flashing display back light to indicate a shorted diode or a complete wire it is similar to TM TM that of BeepLit Co...

Page 10: ...th connections Probe Contact EF Detection For more precise indication of live wires such as distinguishing between Live and Ground connections use one single probe to test via terminal COM for direct...

Page 11: ...is mode Auto Power Off is disabled automatically in this mode 19 C 5ms CREST MODE Press CREST button for one second or more to activate CREST mode instantaneous PEAK HOLD to capture current or voltage...

Page 12: ...E To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case WARNING If the...

Page 13: ...authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered...

Reviews: