08

RESISTANCE

600.0  

±(1.0%rdg + 5dgts)

Accuracy

Resolution

Range

0.1  

6.000K

Open Circuit Voltage :

 1.0VDC typical

1     

TM

BeepLit  CONTINUITY TESTER

Between 30

 & 480

Continuity Threshold

Continuity ON 
Response Time

Audible Indication

Visible Indication

15ms approx.

Beep sound

LCD Backlight

Indication :

 Bar-graph segments & audible beep tones proportional to the field strength.

Detection Frequency :

 50/60Hz

Detection Antenna :

 Inside the top side of the stationary jaw

Probe-Contact EF-Detection : 

For more precise indication of live wires, such as 

distinguishing between live and ground connections, use one single probe to test via 
terminal COM for direct Metal Probe-contact EF-Detection  to achieve the most 
distinctive indication.

NON-CONTACT EF-DETECTION

Bar-Graph

Indication

Typical Voltage (Tolerance)

10V (2V~20V)

40V (8V~70V)

160V (>40V)

20V (4V~40V)

80V (16V~140V)

-

- -

- - -

- - - -

- - - - -

EF-H

(Hi Sensitivity)

EF-L

(Lo Sensitivity)

40V (10V~70V)

160V (40V~280V)

500V (>160V)

80V (20V~140V)

320V (80V~560V)

09

VI. PRODUCT DESCRIPTION :

This  manual  uses  only  representative  model(s)  for  illustrations. 
Please refer specification details for function availability to this model.

1. Antenna  area  for  Non-Contact  EF-

Detection

3. Push-buttons for special functions &

features.

5. 3-5/6   digits   6000   counts  numeric

LCD display.

6. Input Jack for all functions EXCEPT

non-invasive current functions.

7. Common (Ground reference) Input

Jack  for  all  functions EXCEPT the 
Clamp-on current  and Non-Contact 
EF-Detection functions.

8. Jaw trigger for opening the clamp jaw.

9. Hand/Finger  Barrier  to  indicate  the

limits of safe access of the meter.

10. Clamp  Jaw  for  Clamp-on current

magnetic field pick up.

11. Additional  center  indicator  for 

TM

AmpTip   Low-current  function,  at

TM

where best AmpTip  current accuracy
is specified.

2. Jaw  center  indicator with DCA polarity 
     at where best current  accuracy is 
    specified.

4. Rotary  Selector  to  turn   the  power 

ON/OFF and Select a function.

OFF

MAX 600A
600V CAT III

300V CAT IV

A

Hz

COM

+

300V CAT IV

6.0.3.3

600V CAT III

SELECT

V

V

CREST

REC

EF

A

3

7

6

5

4

3

8

9

10

11

1

2

+

+

Summary of Contents for KM 035

Page 1: ...or Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproo...

Page 2: ...nd CAT IV 300V AC DC TERMS IN THIS MANUAL WARNING Identifies conditions and actions that could result in serious injury or even death to the user CAUTION Identifies conditions and actions that could c...

Page 3: ...lled before the main fuse or circuit breaker in the building installation 03 II CENELEC Directives The instruments conform to CENELEC Low voltage directive 2014 35 EU Electromagnetic compatibility dir...

Page 4: ...s APO Consumption typical 5 A Dimension 188 L x 66 W x 32 H mm Weight approx 202 gms 05 SAFETY Safety Certified per IEC UL CSA_C22 2_ EN standards 61010 1 Ed 3 0 61010 2 032 Ed 3 0 61010 2 033 Ed 1 0...

Page 5: ...readings if any Range 1 2 Accuracy Resolution 2 0 rdg 5dgts 0 1 A 600 0 A 07 600 0 V 1 0 rdg 5dgts DC VOLTAGE Accuracy Resolution Range 0 1 V Input Impedance 10M 100pF nominal AC VOLTAGE with Digital...

Page 6: ...V 500V 160V 80V 20V 140V 320V 80V 560V 09 VI PRODUCT DESCRIPTION This manual uses only representative model s for illustrations Please refer specification details for function availability to this mod...

Page 7: ...of only one single pole of a circuit for load current measurements Make sure the jaws are completely closed or else it will introduce measure ment errors Enclosing conductors of more than one pole of...

Page 8: ...AT IV A Hz COM 300V CAT IV 28 0 600V CAT III SELECT V V CREST REC EF A A 1 Press SELECT button momentarily to select DCA function 13 OFF MAX 600A 600V CAT III 300V CAT IV A Hz COM 300V CAT IV 32 600V...

Page 9: ...ing further drops below 0 100V the meter gives a continuous beep tone together with flashing display back light to indicate a shorted diode or a complete wire it is similar to TM TM that of BeepLit Co...

Page 10: ...th connections Probe Contact EF Detection For more precise indication of live wires such as distinguishing between Live and Ground connections use one single probe to test via terminal COM for direct...

Page 11: ...is mode Auto Power Off is disabled automatically in this mode 19 C 5ms CREST MODE Press CREST button for one second or more to activate CREST mode instantaneous PEAK HOLD to capture current or voltage...

Page 12: ...E To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case WARNING If the...

Page 13: ...authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered...

Reviews: