background image

9

3BA00221 • 2014-09-18 • Rev. 5 

ersa i-CON2 & i-CON 2V

4.4 

Contrast

Do the following to adjust the display contrast individually 
based on the work environment:

 

Turn the station on and immediately turn the i-OP. This 
will activate the contrast mode:

The buzzer tells you that the contrast mode is on.

 

Adjust the contrast as needed by turning the i-OP.

 

Confirm your choice by pressing the i-OP.

5. 

Editing parameters

To edit the value of a parameter, do the following:

 

Press the i-OP to turn on the soldering iron that you 
wish the edit the parameters on.

 

Press and hold down the i-OP for approximately 2 

seconds.

 

Select the required parameter by turning the i-OP.

 

Turn the cursor on by pressing the i-OP. If you press it again the cursor 

will switch off.

When the cursor is on, the value of the parameter is changed by turning the i-OP.

2

0

_

1

0

_

1

0

_

0

2 s

1

0

_

♪!

2

♪!

0

2s

0

0,5 s

3

0

_

2

0

_

Operating modes

Summary of Contents for Ersa i-CON 2

Page 1: ...Phone 49 9342 800 147 Leonhard Karl Str 24 Fax 49 9342 800 252 97877 Wertheim Germany Cell 49 171 2418468 Hotline 24 h www ersa com service tools kurtzersa de Ersa i CON 2 i CON 2V Soldering station Q...

Page 2: ...on 6 3 1 Use 6 3 2 Language selection 6 3 3 Selecting the soldering iron 7 3 4 Setting the temperature 7 3 5 Soldering 7 4 Operating modes 8 4 1 Work mode 8 4 2 Parameter mode 8 4 3 Configuration mode...

Page 3: ...uctions in a safe place which is accessible to all users at all times 1 1 Meanings of symbols The following symbols are used in this quick guide These mark the sections of the text containing explanat...

Page 4: ...on the plate Make sure the soldering iron tip is in the correct position Turn the soldering station off from the mains switch Two soldering irons can be connected to soldering station i CON 2 Accordin...

Page 5: ...soldering sta tion and power outlet Turn the soldering station on Attention Danger of burns The soldering iron tips heat up immediately after the device is switched on 2 3 Connect compression unit C1...

Page 6: ...es the se lected values by 10 50 100 units based on the respective parameters The i OP can also be additionally equipped with a key function Through this key function by pressing it the selected param...

Page 7: ...as been changed 3 3 Selecting the soldering iron Select the required soldering iron by pressing the i OP Pressing the i OP again will turn on the soldering iron connected to the left or to the right 3...

Page 8: ...ation will automatically switch to work mode 4 2 Parameter mode Press and hold the i OP down for approximately 2 seconds to activate the parameter mode for the soldering iron 4 3 Configuration mode Sw...

Page 9: ...ng the i OP Confirm your choice by pressing the i OP 5 Editing parameters To edit the value of a parameter do the following Press the i OP to turn on the soldering iron that you wish the edit the para...

Page 10: ...tart up frequently The vacuum system is not tight Check the seal of the hermetic cap the connections and flexible hoses The CU100 pump does not start up Check the electrical power supply Check the fus...

Page 11: ...11 3BA00221 2014 09 18 Rev 5 ersa i CON2 i CON 2V 7 i Tool 7 1 Replacing the hot tip of the soldering iron 7 2 Replacing the cold tip of the soldering iron 40 C 72 F OFF 40 C 72 F _ 0 _ ON i Tool...