Help
More
More
Date / Time
Date / Time
Date / Time
Digital Multimeter
Voltage
Insulation
a/b: 0,0 V
a/b: 0,0 V
a/b: 0,0 V
Resistance
Capacitance
Current
Loop Analysis
3
4
5
6
Voltage
1
Insulation
2
A-B
Probe
A-B
Probe
0,000 V
< 1 M
W
100V
TestV
Operating Manual
KE3500
xDSL
M
ULTI
T
EST
Digital Multimeter
The large number of measurements allows a detailed error
analysis and a complete overview of the electrical status of the
line under test.
Voltage
The purpose of this study is to measure the direct (DC) and
alternating current (AC) external voltages that may be present
on the cable.
Measurement method
Connect the wires to be measured and the shield of the cable.
Select
Voltage
and press
SEL
. The measurement starts
automatically thereafter. Up in the display the specification of
the used copper parameter is shown. The results of AC and
DC voltage are displayed in volts. Under
F2
Probe
you may
select from differential voltage measurements between the
two wires of a pair (A-B) and the common mode voltage, as
measured between a pair of conductors and the ground (A-
GND, B-GND).
Insulation
In this setting KECT3 measures the insulation resistance
between the two wires running a pair of wires and the
individual wires and ground.
Measurement method
Connect the wires to be measured and the shield of the cable.
Select
Insulation
and press
SEL
. The measurement starts
automatically thereafter. Up in the display the specification of
the used copper parameter is shown.
The results are displayed in ohm. Under F2 Probe you may
select from differential voltage measurements between the
two wires of a pair (A-B) and the common mode insulation
resistance, as measured between a pair of conductors and
the ground (A-GND, B-GND). With F3 Test V, the test voltage
can be changed from 100 V to 30 V.
Resistance
The purpose of this measurement is to determine the loop
resistance.
Measurement method
Connect the wires to be measured and the shield of the cable.
The far end of the measuring wire pair must be shorted, you
have to work with a second Person or with the KE900 Remote-
Unit.
More
Date / Time
a/b: 0,0 V
A-B
Probe
0,810
W
4,915 m
Off
Sense
A-B
A-Gnd
B-Gnd
Resistance
Y(ST)Y_4x2x06
26
KURTH ELECTRONIC Test & Measurement www.kurthelectronic.de [email protected]
DC
Area
None
Term
DC
AC
AC TP
8V
100V
On
Off
None
100
W
DC