28
|
Error
Cause
Solution
1
When the machine is turned on, the power-on
lamp is off, the fan is working.
the power-on lamp is damaged, incorrectly
connected.
replace the indicator lamp, check the wiring
circuit.
the power pcB is damaged.
repair / replace the power pcB.
2
When the machine is turned on, the power-on
light is on, the fan is not working.
the fan is blocked by a foreign object.
remove the object.
the fan motor is damaged.
replace the fan.
3
the power-on lamp does not light when the
machine is turned on, the fan does not work.
No output voltage.
check the network connection.
overvoltage in the network.
check the network connection.
4
No output voltage at terminals.
damaged power pcB.
check the power section of the machine.
5 the arc cannot be ignited.
the welding cables are not
connected.
connect both welding cables.
the welding cables are damaged.
repair / replace damaged cable.
the ground cable is not connected.
check the grounding cable
connection.
6
the arc is difficult to ignite.
Welding cables are incorrectly connected.
check the connection.
the work clamps are covered with dirt.
check and clean the work clamps.
7 unstable arc.
arc power too low.
increase the welding current.
8 the welding current cannot be set.
damaged control potentiometer or loose control
n-coder.
repair / replace potentiometer; pull the n-coder.
9 insufficient material penetration.
Welding current too low.
set the correct welding current.
the arc is too small.
increase the welding current.
10
the fault / overheat indicator is on.
overheating of the machine.
use interval welding.
operating/duty cycle was too long.
Wrong output voltage.
check / replace the power section of the machine.
error messages
Error
Error code
Description
temperature sensor
e01
sensor overheating 1
e02
sensor overheating 2
e03
sensor overheating 3
e04
sensor overheating 4
e09
machine overheating
Welding machine
e10
phase error
e11
Water cooling error
e12
protective gas error
e13
undervoltage in the network
e14
overvoltage in the network
e15
current overvoltage
e16
Wire feeder overload
Buttons
e20
control panel button error
e21
other control of panel error
e22
Welding torch error
e23
Welding torch error during welding process
accessories
e30
cutting torch disconnected
e31
Water cooling disconnected
communication
e40
problem of communication between feeder and source
e41
communication error
en
Summary of Contents for MAKin 250 DP