![Kuhnke PG 674 Instruction Manual Download Page 39](http://html1.mh-extra.com/html/kuhnke/pg-674/pg-674_instruction-manual_2009573039.webp)
4 - 21
Programming
4.6.14. Deleting outputs
Delete all cams programmed for one output in a program. You
must set program number and output before you can delete the
cams.
Example:
program 0, output O0.00
Press
Display
Note
delete prog = 1
delete outp = 2_
program or output?
Delete O:0.00 ?
Yes=ENT No=ESC_
delete output
Pos:312 O:0.00
P00 n:0000 rpm
deletes output
4.6.15. Deleting programs
Delete all cams contained in a program. You must set the pro-
gram number before you can delete the cams.
Example:
program 0
delete prog = 1
delete outp = 2_
program or output?
Prg.00 delete ?
Yes=ENT No=ESC_
delete program
Pos:312 O:0.00
P00 n:0000 rpm
deletes program
Summary of Contents for PG 674
Page 6: ...Contents 4 Table of contents ...