![Kuhnke PG 674 Instruction Manual Download Page 31](http://html1.mh-extra.com/html/kuhnke/pg-674/pg-674_instruction-manual_2009573031.webp)
4 - 13
Programming
4.6.7.2. Changing the program number
Press
Display
Note
SHIFT
controller STOP?
Yes=ENT No=ESC_
"NO" cancels the function
program act.:0
des.:_
program act.:0
des.:1_
possible entries: 0...7
Pos:261 O:0.00
P00 n:0000 rpm
choice of program OK
If there is no access right (see ch. 4.6.7.1.), then the following message will ap-
pear briefly:
CODE ERROR
???
then the device will resume the standard display with the un-
changed program number:
Pos:261 O:0.00
P00 n:0000 rpm