ORIGINAL OPERATING INSTRUCTIONS
Commissioning
March 3, 2018
38/55
7.12 Weighing of spreading materials
Pos.
No.
Function
10
Specification of conveyor screw (left/right)
20
Pulses
30
Spread quantity [kg]
40
Pulses/kg
50
Press to confirm and calculate again
60
Setting of spread quantity (Pos. 40)
70
Setting of pulses/kg
1
Fill in spreading material into the spreader and put a reservoir that is
appropriately large under the screw conveyor outlet.
2
Start spreading operation (see Chapter
8.6 "Start spreading", page 49
until the screw tunnel is filled.