ORIGINAL OPERATING INSTRUCTIONS
Commissioning
March 3, 2018
21/55
1 Fit operating unit (Pos. 40) at appropriate place in the carrier vehicle.
2 Fit connection box (Pos. 50) at an appropriate place outside the cabin (ideally
close to the hydraulic connectors).
3 Fix both junction boxes at an appropriate place in the cabin of the carrier vehicle
(ideally next to the control system (Pos. 40)).
4 Lay cables in the carrier vehicle to the junction boxes and connect them with the
boxes.
Caution
Laying of cable.
Danger of property damage.
•
Lay the cable over the pivot of the cabin in order to avoid damage during
tilting!
Hinweis
The terminal diagram is located in the connection box (Pos. 50).
5 Connect connecting cable (Pos. 20) with the spreader.
6 Connect connecting cable (Pos. 30) with the spreader.
7 Take drive signal / power supply (Pos. 10) from the carrier vehicle.
– Red = +12 V / socket contact no. 1
– Brown = 0 V (ground) / socket contact no. 2
– Red/white = drive signal (speed signal) / socket contact no. 3
Caution
Connecting to power supply.
Danger of property damage.
•
Please make sure that, in the positive cable, a fuse is attached as close to the
battery as possible (max. 15 A)!
8 Plug in the connecting cables (Pos. 10, 20, 30) at the junction boxes in the cabin.
9 Connect the connecting cables of the spreader at the connecting box (Pos. 50).