KFU 210- / 410-
36
572
Frequency Limit Motor Circuit
Breaker
0%
300%
0%
722
Integral Time 1
0 ms
60000 ms
-
4)
728
Current Limit
0.0 A
ü
I
FUN
1)
ü
I
FUN
1)
No.
Description
Setting
Factory setting
30
Configuration
110 –
sensor-less control
110
410 –
sensor-less field oriented
regulation
For further configurations (incl. servo
motors), refer to Operating Instructions.
34
Program(ming)
111 –
Parameter transmission
110
110 –
Standard operation
123 –
Reset
4444 – Reset parameter
369
Motor Type
0 –
Unknown
1
1 –
Asynchronous
2 –
Synchronous
3 –
Reluctance
10 –
Transformer
452
Op. Mode Multifunction Input
1 –
Voltage Input
1: Standard value in
Configuration 110 and
410.
Other configurations
may deviate.
2 –
Current Input
3 –
Digital input
530
Op. Mode Digital Output 1
see Operation Instructions
532
Op. Mode Digital Output 3
553
Analog Operation MFO1
570
Motor Temp. Operation Mode
0 –
off
0
1 –
Therm.-Cont.: Warning only
2 –
Error switch-off
3 –
Err.Switch-Off 1 min delayed
4 –
Err.Switch-Off 5 min delayed
5 –
Err.Switch-Off 10 min delayed
571
Operation Mode Motor Circuit
Breaker
see Operation Instructions
645
Operation Mode Synchronization
see Operation Instructions
651
Operation mode Autostart
0 –
off
0
1 –
On
670
Operation mode of voltage
controller
0 –
off
0
1 –
DC link limitation active
2 –
Power regulation active
3 –
Ud lim. & mains support active
12 –
Mains support active, without
chopper
13 –
Udc-Lim. & Mains Supp. active,
Chopper not active