Maintenance
130
Pendulum axis and fork
bearings
On the spreading spout side of the spreading unit there are:
•
2 grease nipples on the fork bearing housings; left and right next to
the spreading spout mounting flange.
•
and 1 grease nipple on the bearing housing of the central
pendulum axis
Dosing baffle
The dosing openings are opened and closed through a dosing plate
situated below that rotates.
Grease the plate after every cleaning:
Close the dosing
Apply the oil to the dosing plate through the 3 holes in the
spreading plate.
subsequently open and close the dosing repeatedly.
The oil is distributed over the plate surface.
Grease nipples on fork bearing housing (left & right)
Grease nipple on the pendulum axis bearing housin
Dosing plate closed
Spreading plate with 3 holes