![Kubota M5-091 Operator'S Manual Download Page 40](http://html1.mh-extra.com/html/kubota/m5-091/m5-091_operators-manual_2008844040.webp)
16
OPERATING THE ENGINE
B
Operating Procedure for Regeneration Inhibit Mode
C
Regeneration Operating Procedure
(1) Parked regeneration switch
(2) DPF INHIBIT switch
(3) Regeneration indicator
(4) Parked regeneration indicator
(5) Engine RPM increase indicator
(6) Engine warning indicator
1.
Start the engine.
2.
Press the DPF INHIBIT switch
, and the switch lamp illuminates.
Switch lamp ON: Regeneration Inhibit Mode selected.
Switch lamp OFF: Auto Regeneration Mode selected.
3.
When the parked regeneration indicator
starts flashing:
A specific amount of PM has accumulated in the DPF muffler.
Move the tractor to a safe place and activates the DPF muffler. Follow the "Operating Procedure for Parked
Regeneration" procedure.