140
W9215-8135-1
06/2021
Maintenance
Topping up hydraulic oil
All hydraulic cylinders have to be extended half way (see fig-
ure), the boom has to be in line with the excavator, the dozer
blade has to be lowered to the ground and the extendable track
width has to be set to standard track width.
Open the engine hood (page 112).
Remove the oil filler cap (1).
Insert a clean funnel into the filler port.
Fill hydraulic oil to half way up the sight glass (1).
Screw in the oil filler cap.
Start the excavator and operate all control functions.
Check again the oil level of the hydraulic system.
Close the engine hood and secure it with a padlock.
Pay attention to utmost cleanliness when servicing the hydraulic system.
Danger of injury from liquids under pressure!
Escaping hydraulic oil under pressure can penetrate into the skin.
- Do not cover apertures, e.g. ventilation systems, and hot components.
Risk of burns from hot components!
Surfaces can be hot and lead to burns.
- Do not touch hot parts, such as exhaust muffler, etc.
This service may only be carried out after the hydraulic oil has cooled down.
STOP
STOP
STOP
1
1
Summary of Contents for K008-5
Page 1: ...GB COMPACT EXCAVATOR MODELS K008 5 U10 5 OPERATING INSTRUCTIONS W9215 8135 1 Original 06 2021...
Page 14: ...12 W9215 8135 1 06 2021 General information...
Page 36: ...34 W9215 8135 1 06 2021 Safety rules...
Page 50: ...48 W9215 8135 1 06 2021 Description of the excavator...
Page 127: ...Maintenance W9215 8135 1 125 06 2021...
Page 152: ...150 W9215 8135 1 06 2021 Maintenance...
Page 154: ...152 W9215 8135 1 06 2021 Safety inspection...
Page 162: ...160 W9215 8135 1 06 2021 Lifting capacity of the excavator...
Page 167: ...Accessories W9215 8135 1 165 06 2021...
Page 168: ......