4.
Connect the digital meter (A) (optional: P/N RB257-5311-0) and the switches (B) (optional:
P/N: RB257-5322-0) with the wire harness (C) (optional: P/N: RA058-9661-0).
5.
Insert red key into the starter switch.
6.
Press the selector switch connected with the red and blue colour wire harness.
Do not turn the key at this point. If the key is in the RUN position, turn it back to the STOP position.
B
A
C
I
II
III
A
Digital meter
I
12-pin connector to connect with the digital me-
ter
B
Switches
II
4-pin connector to connect with the switches
C
Wire harness
III
8-pin connector to connect with the coupler for
the key register