15
-
Error
codes
Occurring Error
562
567
572
557
Check point
Action
Recovery verification
Sold-out
columns
―
Compartment 1
delivery thermistor error
Compartment 2
delivery thermistor error
Compartment 3
delivery thermistor error
Compartment 4
delivery thermistor error
Check compartment 1 delivery
thermistor connector for
disconnection.
Check compartment 2 delivery
thermistor connector for
disconnection.
Check compartment 3 delivery
thermistor connector for
disconnection.
Check compartment 4 delivery
3208
Move insulation
detection of SW
abnormal
Check setting of Hot / Cold
Check SW of move insulation
Change setting of Hot / Cold
Change checking SW of move
insulation
Check power failure code
3209
Fixed insulation
detection of SW
abnormal
Check setting of Hot / Cold
Check SW of fix insulation
Change setting of Hot / Cold
Change checking SW of fix
insulation
thermistor connector for
disconnection.
Reconnect harness.
If there seems to be no problem,
replace the thermistor.
(CAUTION: Always reset the
machine by switching the power
ON/OFF after corrective action.)
Error code cleared.
Error codes and Corrective Actions
Other
Error
codes
Occurring Error
3220
Noise Filter board fuse
blown detection error
If there seems to be no problem,
replace the Noise Filter board.
Check Noise Filter board
Error code cleared.
Check point
Action
Recovery verification
Sold-out
columns
―
3022-75198-00
TPK
Vending
Corporation
Co.,
Ltd.