background image

-1-

Switching HOT

COLD temperature setting

* Unused. It is only for cooling

Press to switch on/off powerful operation.
LED will turn on while powerful operation is activated.

Powerful operation will be cancelled in 2 hours from activation.

Press to select lighting settings from "ON", "AUTO", or "OFF".
LED for corresponding setting will indicate the setting. Both LEDs will turn on when it is set in "OFF".

Unused

LED will turn on, when condenser malfunction is detected.
Please check and clean the condenser, and then press the key after it is done.

Condenser is normal when the LED is not on.

Total amount for each counter from G1 to G10 could be viewed by pressing the key.

View Counter

Press "Counter" key to view counters for each grouping.

1.

Counter will indicate total amount at first. Press "Counter" key to show count by grouping.

  

show count by grouping.

2.

Next counter will be displayed by pressing the key again.

3.

Indicated counter will return to that of total after the final counter.

Example: 

1 counter 

 G1    345678 

 Temperature setting switch 
* Unused. It is only for cooling

Press to select test mode

Press to stop vending

Unused

Modify settings and data

1.Press to perform diagnostics
2.Press continuously for more 

     than 2 seconds to clear data

1.Select mode function
2.Start/Stop test vend

Flashes in case of malfunction

1.Date,hour,and total sales 

     

count will displayed during idling.

2.Failure type and number of 

     failures will be displayed in case
     of malfunction occurrence

Press to select sales count mode

Press to select alternative sales

Press for price setting mode

Modify settings and data

Press to confirm

End key board operation

LED indicate the activated function

・Stop vend
・alternative sales
・column-selection

Part descriptions and function

TPK 

Vending 

Corporation 

Co., 

Ltd.

Summary of Contents for GF-41S

Page 1: ...Count View Lifetime Vend Count Set View Suspend Vending Hours Column Key Number 0 9 Set View Suspend Vending Mode Set View Alternate Sales Key Number 0 9 Set View Product Pricing View Clear Occurring...

Page 2: ...to show count by grouping show count by grouping Next counter will be displayed by pressing the key again Indicated counter will return to that of total after the final counter Example 1 counter Tempe...

Page 3: ...xts on operating procedures 3 Operation is complete when it is allowed to stand for about 30 seconds which will be automatically complete 4 Use the correct mode for setti ng and clearing data Using th...

Page 4: ...icator Function Note Single Test Vend Key Number 0 9 Coin Test Vend Key Number 0 9 Consecutive Test Vend Selection button Consecutive Test Vend Keyboard operated Sequential Test Vend press once press...

Page 5: ...ount Group Sales Value will also be cleared at the same time If total vends exceed 6 digits only the lower 6 digits will be displayed Single Test Vend Key Number 0 9 Key Indication Operation Press Tes...

Page 6: ...s Press Set Price Key Press UP or DOWN Key to select pricing After inputting the column number to be set using Ten Key press Enter Key If you want to check a specified column press Enter Key Column nu...

Page 7: ...cancel the setting input 0 and press Enter key on the column number when it is active Press UP or DOWN Key to move on to next group Key Number For Sound Operation Setting Proce dure Key Indication Op...

Page 8: ...B Pattern Time Range 4 b5 B Pattern Time Range 5 b6 B Pattern Time Range 6 b7 B Pattern Time Range 7 C1 C Pattern Time Range 1 C2 C Pattern Time Range 2 C3 C Pattern Time Range 3 C4 C Pattern Time Ran...

Page 9: ...ress END Key to return to normal operation Press UP or DOWN Key to select function number Press UP or DOWN Key to set start time Press Set Key Press UP or DOWN Key to set end time Press Set Key System...

Page 10: ...en start time and end time of light saving hour is set to same time NOTE Set Lighting Setting switch to AUTO Proce dure Key Indication Operation Press END Key to return to normal operation Press Mode...

Page 11: ...ey Press Set Key to confirm setting Press UP or DOWN Key to select illumination ending hour Lower 2 digits are the ending hour Press Set Key to confirm setting Selectable hours are from 0 24 When begi...

Page 12: ...rst set the current date month Preservation Quality Period Proce dure Key Indication Operation Press Mode Key Press Set Key Set View Stop Vending Amount of Days Before Preservation Quality Period 6 Pr...

Page 13: ...problem replace the coin mech If there seems to be no problem replace the coin mech If there seems to be no problem replace the selector or coin mech Check harness and connectors for disconnection Ch...

Page 14: ...ery unit communication error Printer communication error Keyboard unit communication error Bill validator communication error Card unit communication error If there seems to be no problem replace the...

Page 15: ...r Check compartment 3 fan motor Check compartment 4 fan motor Check condenser fan motor Check condenser thermistor connector for disconnection Check condenser external thermistor connector for disconn...

Page 16: ...tting of Hot Cold Change checking SW of move insulation Check power failure code Fixed insulation detection of SW abnormal Check setting of Hot Cold Check SW of fix insulation Change setting of Hot Co...