R60076.0002
–
Index 1
Page 19 / 24
All pictures in this section assume that the A/B divider is set to 8. The Z Pulse is divided
according to its divider (additionally DIL2/1 on OFF, ZIN is used, Z dividers not complete on
OFF).
Depending on the length or location of the Z Pulses input and through the synchronization to
the input or output signals, the Z pulse at the output can fluctuate around an input or output
period (not with DIL1/5 = DIL1/4 = ON).
DIL1 Front
8-pole
Wide Z pulse (a full encoder turn)
4
5
ON
ON The pulse width at the output corresponds to the full distance between two Z
pulses at the input.
DIL1 Front
8-pole
Narrow Z pulse (1/4 output-periode)
(Only applicable to input signals A/B 90°, DIL1/6 = OFF)
4
5
OFF ON The pulse width at the output corresponds to ¼ period of pulse width at the input.
DIL1 Front
8-pole
Narrow Z pulse (1/4 output-periode)
(Only applicable to output signals A/B 90°, DIL1/7 = OFF)
4
5