Input and output configuration
Changes in the settings on the DIL switches will only be taken over by the
device after the supply voltage has been switched on again!
Configuration
DIL1 (Front 8-pole)
Function
1
2
3
4
5
6
7
8
ON
Level for HTL Single Ended: U
L
< 10V / U
H
> 14V
OFF
Level for HTL Single Ended: U < 5V / U > 9V
ON ON
Input format: TTL
ON OFF
Input format: HTL Single Ended
OFF ON
Input format: RS-422
OFF OFF
Input format: HTL Differential
ON ON
Z-pulse length: 1 Z-Puls, independent of A / B
OFF ON
Z-pulse length: ynchronized with AOUT / BOUT
ON OFF
Z-pulse length: synchronized with AIN / BIN
OFF OFF
Z-pulse length: 1 Z-Puls, a depending on A/B
ON
Input Mode : A/B Dir (Pulse / Direction)
OFF
Input Mode : A/B 90°
ON
Output Mode : A/B Dir (Pulse / Direction)
OFF
Output Mode : A/B 90°
ON ZERO_A : Zero setting delayed, no errors
OFF
ZERO_A : Zero setting immediately, error
possible
ON Highest divider for A / B divider on (2048)
OFF Highest divider for A / B divider off (2048)
Configuration
DIL2 (Front 3-pole)
Function
1
2
3
ON
Z-pulse: Generation of a Z-pulse from AIN & BIN, AOUT & BOUT
OFF
Z-pulse: Z input is used
OFF
Test mode deactivated: OFF
ON
Output format : HTL Differential, HTL Single Ended (
UX1(2)
–
2V)
OFF
Output format: RS-422, TTL (5V)