Level converter A/B Pulse (A/B Divider: All OFF)
If the A/B pulse have to be switched unchanged from the input to the output (no division, no
change in length and position), then the DIL switch position listed below must be chosen. A
level conversion is only possible if the input mode (A/B 90 ° or A/B dir) corresponds to the
output mode. (DIL1/6 = DIL1/7).
Divider [A/B]
DIL5
(Left 8-pole)
DIL6
(Left 3-pole)
DIL1
(Front)
Comment
1
2
3
4
5
6
7
8
1
2
3
8
Binary value
1
2
4
8
16
32
64
12
8
25
6
51
2
10
24
20
48
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
OFF
AIN = AOUT, BIN = BOUT
Input/Output Mode Converter (A/B Divider: All OFF)
If input mode differs from output mode and in addition, the DIL switches DIL5 and DIL6 of the
divider A/B are all set to OFF, the following signal characteristics are set up at the output.
Case 1:
Input A/B 90°, Output A/B Dir
DIL1/6 = OFF, DIL1/7 = ON with A/B Divider setting: DIL5, 6 = all OFF
If the direction of the A/B 90 ° signal changes at the input, a change takes place at the BOUT
output signal. (A/B dir). There is no division.
Case 2:
Input A/B Dir, Output A/B 90°
DIL1/6 = ON, DIL1/7 = OFF with A/B Divider setting: DIL5, 6 = all OFF
If a change takes place at the BIN input signal (A/B dir), the direction of the A/B 90 ° signal
changes at the output. Here is a division 1:2, from the input in relation to the output.
Adjustable divider A/B
Setting the A/B Divider (at A/B Dir to A/B 90°)
The division ratio for the A/B pulses is set at the DIL switches DIL5 and DIL6. The switch
positions use a binary code like shown in the subsequent list. (DIL1/6 = ON, DIL1/7 = OFF).