R60076.0002
–
Index 1
Page 15 / 24
Setting the A/B divider (for all other modes)
The division ratio for the A/B pulses is set at the DIL switches DIL5 and DIL6. The switch
positions use a binary code like shown in the subsequent list. (DIL1/6 = OFF, DIL1/7 = X).
Divider [A/B]
DIL5
(Left 8-pole)
DIL6
(Left 3-pole)
DIL1
(Front)
Comment
1
2
3
4
5
6
7
8
1
2
3
8
Binary value
division =>
1 : Binary value +1
1
2
4
8
16
32
64
12
8
25
6
51
2
10
24
20
48
ON OF
F
OFF OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 1 => 1 : 2
OFF ON OFF OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 2 => 1 : 3
ON ON OFF OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 3 => 1 : 4
OFF OF
F
ON OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 4 => 1 : 5
ON OF
F
ON OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 5 => 1 : 6
OFF ON ON OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 6 => 1 : 7
ON ON ON OFF OFF OF
F
OFF OFF OFF OFF OFF
OFF
value 7 => 1 : 8
OFF
...etc.
OFF OF
F
OFF OFF OFF OF
F
OFF OFF OFF ON OFF
OFF
1 : 513
OFF OF
F
OFF OFF OFF OF
F
OFF OFF OFF OFF ON
OFF
1 : 1025
ON ON ON ON ON ON ON ON ON ON ON
OFF
1 : 2048
ON ON ON ON ON ON ON ON ON ON ON
ON
1 : 4096
Example: Input A/B 90°, output A/B 90 ° with A/B division 1:6 (setting DIL6, 5: OFF ON OFF