Battery (MXC/EXC)
The battery is located under the seat and is maintenance-free.
It is not necessary to check the electrolyte level or to refill water. Simply keep
the battery poles clean and slightly grease them with an acid-free grease if
necessary.
Removing the battery:
First disconnect the negative and then the positive pole of the battery.
Remove the filter box cover and unhitch both rubber bands
[1]
.
Remove battery.Install the battery with the terminals facing the front (see illus-
tration), connecting the negative terminal post to the battery last.
– IF ELECTROLYTE (SULPHURIC ACID) LEAKS FROM THE BATTERY, PROCEED WITH
GREAT CARE. THE ELECTROLYTE CAN CAUSE SEVERE BURNS.
– IN THE CASE OF SKIN CONTACT RINSE THOROUGHLY WITH WATER.
– IN THE CASE OF CONTACT WITH THE EYES, THOROUGHLY RINSE EYES WITH
WATER FOR AT LEAST 15 MINUTES. IMMEDIATELY CONSULT A DOCTOR.
– THE BATTERY IS A CLOSED MODEL BUT CAN NEVERTHELESS EMIT EXPLO-
SIVE GASES. AVOID SPARKS AND OPEN FIRE NEAR THE BATTERY.
– DEFECTIVE BATTERIES MUST BE STORED OUT OF THE REACH OF CHILDREN.
ENSURE PROPER DISPOSAL OF DISCARDED BATTERIES.
– TO AVOID DAMAGE, DO NOT REMOVE THE LOCKING BAR
[2]
!
– NEVER DISCONNECT THE BATTERY WHILE THE ENGINE IS RUNNING. THIS
WILL DESTROY THE RECTIFIER-REGULATOR.
– THE BATTERY MUST BE INSTALLED WITH THE TERMINALS FACING THE FRONT
(AS SHOWN IN THE ILLUSTRATION), OTHERWISE ELECTROLYTE CAN ESCAPE.
BATTERY STORAGE:
When preparing the motorcycle for a longer period of standstill, remove the
battery and recharge it. Storage temperature: 0 - 35°C (30 - 95°F). Do not
expose to direct sunlight.
Charging the battery
Remove the battery and check the charging level. Use a voltmeter to
measure the voltage between the battery poles (off-load voltage).
Accurate results can only be obtained if the battery has neither been charged
nor discharged during a period of 30 minutes preceding the measuring.
If the battery is empty, it can be recharged for a maximum period of
10 hours at 0.4 A and a maximum of 14.4 V.
– TO AVOID DAMAGE, DO NOT REMOVE THE LOCKING BAR.
– ALWAYS CONNECT THE BATTERY TO THE CHARGING UNIT BEFORE TURNING
THE CHARGING UNIT ON.
– WHEN RECHARGING THE BATTERY IN CLOSED ROOMS THERE IS SUFFICIENT
VENTILATION. EXPLOSIVE GASES ARE RELEASED DURING THE BATTERY
CHARGING PROCESS.
– CHARGING TIME AND CHARGING VOLTAGE SHOULD NOT EXCEED THE STATED
VALUES. OTHERWISE ELECTROLYTE WILL BE RELEASED THROUGH THE SAFETY
VALVES.
– AVOID QUICK CHARGING IF POSSIBLE.
VOLT
1
2
off load voltage
Volt
charging level
%
charging time
0,4 A
charging voltage
>12,7
~12,5
~12,2
~12,0
~11,8
100
75
50
25
0
––
4 h
7 h
11 h
14 h
Max.
14,4 V
Summary of Contents for 250 EXC
Page 59: ...ENGLISH 58 ...
Page 60: ...ANHANG APPENDICE APPENDIX APÉNDICE 1 SCHALTPLAN WIRING DIAGRAMM ...
Page 61: ...ANHANG APPENDICE APPENDIX APÉNDICE 2 SCHALTPLAN WIRING DIAGRAMM ...
Page 62: ...ANHANG APPENDICE APPENDIX APÉNDICE 3 SCHALTPLAN WIRING DIAGRAMM ...
Page 92: ...2 7E 1 2 3 4 21 23 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 5 22 24 ...
Page 172: ...8 3E CARBURETOR KEIHIN FCR MX 37 39 41 ...
Page 242: ...Repair manual KTM 250 610 Racing Art Nr 3 206 023 E 12 2E ...
Page 243: ...12 3E ...
Page 244: ...12 4E Repair manual KTM 250 610 Racing Art Nr 3 206 023 E ...
Page 245: ...12 5E ...
Page 246: ...Repair manual KTM 250 610 Racing Art Nr 3 206 023 E 12 6E ...
Page 247: ...12 7E ...
Page 248: ...Repair manual KTM 250 610 Racing Art Nr 3 206 023 E 12 8E 250 400 520 MXC EXC RACING 2002 ...
Page 249: ...12 9E Modell 250 400 520 EXC RACING ...
Page 250: ...Repair manual KTM 250 610 Racing Art Nr 3 206 023 E 12 10E 250 400 520 EXC RACING 2002 ...
Page 251: ...250 450 525 MXC EXC 01 02 03 12 11E ...
Page 252: ...12 12E Repair manual KTM 250 610 Racing Art Nr 3 206 023 E ...
Page 253: ...12 13E 250 450 525 EXC Racing 2003 ...
Page 257: ...12 17E ...
Page 258: ...12 18E Repair manual KTM 250 610 Racing Art Nr 3 206 023 E ...