FIELD WIRING
(Please read entirely before wiring)
The MK60SP field wiring can be broken down to 3 systems
1
.
INTERFACE WIRING - KH1010 interface to the KP300 control panel
2.
PUMP CONTROL - simple switch, timer and /or GSM control
3.
GSM INTERFACE (optional) - warning and pump control
KH1010 PCB
WIRING CONNECTIONS
START
CONNECTIONS
INTERFACE WIRING
1. Referencing the MK60SP wiring diagram, a small harness of 8 communication wires plus 2 circuit
protected 12 vdc power and ground wires need to be routed between the KP300 panel and the
KH1010 interface box. (Use an on/off switch to control system power or use the circuit breaker)
2. Fabricate a 10 wire harness using approved 16 awg wire or purchase our cable assembly P/N KW1016
by the foot.
3. After the harness is installed, start making the connections at the KH1010 interface. The interface box
is small in size, so start your connections closest to the cable gland and out
–
12,+12, 8
–
1 etc.
Continue with wiring the KP300 panel.
INTERFACE WIRING