9.3.3
PARAMETER
PARAMETER
NAME
DESCRIPTION
PRESET VALUES
P1
Stand by time
When air is not requested,
compressor stays in stand by
for this time, then stops
180 sec
P2
System temperature
Under this temperature the
system doesn’t stop after
stand by time
60°C
P3
Maximum
temperature
Above this temperature it
appear temperature alarm
100 °C
P4
Fan temperature
Above this value electric fan
starts
75 °C
P5
Maximum system
pressure
Above this value compressor
goes in unload mode
8 barg
P6
Minimum system
pressure
Under this value compressor
goes in load mode
7 barg
P7
Maintenance hours
Is the time setted between one
maintenance and the next
(protected by key parameter,
that is required every time it is
accessed)
500 ore
P8
Maintenance hours
resetting
Enter the code key to reset the
maintenance alarm
Only for maintenance
workers
P9
Hours remaining to
maintenance
It shows hours remaining to
the next maintenance / control
---
9.3.4
STOPPING THE COMPRESSOR
By pressing
for 2 seconds, it appears the following flashing screen:
After 10 seconds, the compressor stops.