Once emptied, close the emptying cap.
Then top up the oil until the right level is read on the window (see figure 13). Then tighten the oil
filling cap once more.
After having replaced the oil and oil filter, run the compressor for about 10 minutes, turn it off and
check the oil level. If necessary, top up.
Figure 13
Never mix different types of oil. Make certain that the oil circuit is completely empty
before performing any maintenance. Always replace the filter at each oil change (chap.
10.6).