code R30020.100en www.kseniasecurity.com
ed.04/2020
FACTORY DATA RESET
On factory data configuration there are no opera remote commands memorized and the outputs are
programmed as independent and bistable.
In order to restore the factory default, hold the programming button on auxi wls for 10 seconds while it is in
normal working mode. The led on device stays steady on, then starts regularly blinking and finally shortly
blinks 3 times, like the first power up. These 3 blinks indicate the reset of factory data and auxi wls returns
to the normal working mode. In case the button is released before the end of procedure (3 blinks), if the
button is released while the led stays lit, auxi wls will enter in the remote commands programming, if the
button is released while the led blinks regularly it will enter in the outputs programming.
In case of factory data reset, auxi wls acts as a wireless peripheral on panel, considering that there are no
remote commands memorized.
CERTIFICATIONS
Europe - CE, RoHs
Technical data, appearance, functionality and other product characteristics may change without notice.