background image

code R30020.100en                                                                                                                                                                           www.kseniasecurity.com
ed.04/2020

By holding for 3 seconds the programming button on auxi wls, it exits from the programming mode of the 
outputs and the device returns to the normal working mode. The led on device blinks at the exit of 
programming mode, as at the start of programming.
NOTE: auxi wls have to be programmed one by one. DO NOT try to program more than one auxi at the same 
time, to avoid conflicts.

INDEPENDENT

MONOSTABLE

BISTABLE

relay output 1

relay output 2

relay output 1

relay output 2

Short press on key 1 of opera 
remote command. Once 
pressed, the first relay 
switches and the led on auxi 
wls starts blinking each 
second. This indicates that 
auxi wls start counting the 
monostable time. By pressing 
again, the relay re-opens and 
the led on auxi wls quickly 
blinks 3 times to confirm the 
configuration saving. The 
monostable time is the time 
elapsed between the two 
press on key.

Short press on key 2 of opera 
remote command. Once 
pressed, the first relay 
switches and the led on auxi 
wls starts blinking each 
second. This indicates that 
auxi wls start counting the 
monostable time. By pressing 
again, the relay re-opens and 
the led on auxi wls quickly 
blinks 3 times to confirm the 
configuration saving. The 
monostable time is the time 
elapsed between the two 
press on key.

Long press on key 1. 
The led on auxi wls 
blinks 3 times to 
confirm the 
configuration saving.

Long press on key 2. The 
led on auxi wls blinks 3 
times to confirm the 
configuration saving.

SPTD Change over switch

INTERLOCKED

MONOSTABLE

BISTABLE

MONOSTABLE

BISTABLE

Short press on key 0 of opera 
remote control. Once 
pressed, the first relay 
switches and the led on auxi 
wls starts blinking each 
second. This indicates that 
auxi wls start counting the 
monostable time. By pressing 
again, the relay re-opens and 
the led on auxi wls quickly 
blinks 3 times to confirm the 
configuration saving.
The monostable time is the 
time elapsed between the 
two press on key.

Long press on key 0 of 
opera remote control. 
The led on auxi wls 
quickly blinks 3 times 
to confirm the 
configuration saving.

Short press on key (i) of opera 
remote command. Once 
pressed, the first relay 
switches and the led on auxi 
wls starts blinking each 
second. This indicates that 
auxi wls start counting the 
monostable time. By pressing 
again, the relay re-opens and 
the led on auxi wls quickly 
blinks 3 times to confirm the 
configuration saving. The 
monostable time is the time 
elapsed between the two 
press on key.

Long press on key (i) of 
opera remote control. 
The led on auxi wls 
quickly blinks 3 times to 
confirm the 
configuration saving.

Summary of Contents for auxi wls KSI2300002.300

Page 1: ...generally any load unreachable by cables auxi wls can be used in conjunction with lares 4 0 control panels or as a stand alone device In the second case the outputs can be controlled locally using th...

Page 2: ...ROL PANELS Depending on its size lares 4 0 control panels can manage up to 64 auxi wls The activation of the outputs can be managed through scenarios or using the built in inputs on auxi wls Inputs pr...

Page 3: ...CONTACTS STAND ALONE LARES 4 0 What follows is valid only for using auxi wls as stand alone device or as peripheral on Panel without associated zones see above In case of independent or interlocked ou...

Page 4: ...t or SPTD change over switch the ON time is re started Otherwise it turns off if the output is programmed as interlocked If the output is programmed as bistable it commutates at every press on the key...

Page 5: ...ipheral of the panel the led turns OFF Once the starting phase is over the led indicates the reception of a valid radio command 0 1 2 keys In case the outputs are programmed as independents a short pr...

Page 6: ...seconds The led on device stays lit to confirm the access on programming mode Hold the key i on remote command for 3 seconds in order to memorize it The led on auxi wls blinks 4 times to confirm the m...

Page 7: ...to confirm the configuration saving The monostable time is the time elapsed between the two press on key Long press on key 1 The led on auxi wls blinks 3 times to confirm the configuration saving Lon...

Page 8: ...rst power up These 3 blinks indicate the reset of factory data and auxi wls returns to the normal working mode In case the button is released before the end of procedure 3 blinks if the button is rele...

Reviews: