8 Trouble-shooting
51 of 64
MK
A B C D E
F Possible cause
Remedy
11)
-
✘
-
-
✘ ✘
Pump is warped or sympathetic vibrations in
the piping.
▪
Check pipeline connections and secure
fixing of pump; if required, reduce the
distances between the pipe clamps.
▪
Fix the pipelines using anti-vibration
material.
-
✘
-
-
✘
- Defective bearing(s)
▪
Replace the bearing(s). If required, re-
install the shaft upside down.
-
✘
-
-
-
✘
Pump clogged by sand, dirt in the pump
sump.
▪
Clean the intake, pump components and
lift check valve.
▪
Drain and clean the pit.
-
-
-
-
✘ ✘
Rotor is out of balance, shaft is warped
▪
Clean the impeller.
▪
Re-balance the impeller.
▪
Fit a new shaft.
-
✘
-
-
-
- Current exceeds the value set in the motor
protection switch.
▪
Set the motor protection switch to the
nominal value given on the name plate of
the motor.
-
-
✘
-
-
- Excessive temperature of the fluid handled
▪
Lower the fluid temperature.
-
-
-
-
-
✘
Aggressive fluid
▪
Use other bearing material.
-
-
-
-
-
✘
Abrasive fluid
▪
Use different bearing material, if necessary.
▪
Supply flushing water (lubrication by
external fluid).
-
-
-
-
✘
- Cavitation (rattling noise)
▪
Check steam trap.
▪
Increase suction head.
▪
Reduce condensate temperature.
▪
Increase back pressure by throttling.