5 Installation at Site
25 of 64
MK
DANGER
Electrostatic charging
Explosion hazard!
Damage to the pump set!
▷
Connect the potential equalisation conductor to the earthing terminal
provided.
▷
Make sure that the connection between pump and baseplate is electrically
conductive.
▷
Screws, bolts, nuts and shims must not be coated or the coating must be
removed.
▷
Provide potential equalisation between the pump set and the foundation.
DANGER
Electrical connection work by unqualified personnel
Risk of fatal injury due to electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof models, EN 60079.
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
NOTE
A motor protection device is recommended.
1. Check the available mains voltage against the data on the motor name plate.
2. Select an appropriate starting method.
5.8 Checking the direction of rotation
DANGER
Pump set running dry
Explosion hazard!
▷
Check the direction of rotation of explosion-proof pump sets outside
potentially explosive atmospheres.
WARNING
Hands inside the pump casing
Risk of injuries, damage to the pump!
▷
Always disconnect the pump set from the power supply and secure it against
unintentional start-up before inserting your hands or other objects into the
pump.