7 Servicing/Maintenance
42 of 64
MK
CAUTION
Damage to the shaft assembly
Warping of the shaft!
▷
Support the shaft assembly if the shaft is long.
1. Remove any lubricating lines.
2. Remove level control equipment, if any.
3. Remove screw plug 903.01 with joint ring 411.01 from radial bearing 303.02 and
303.03 (if any).
4. Undo nuts 920.11.
5. Unscrew the discharge pipe from the volute casing 102. Note discs 550.11 and
gaskets 400.11.
6. Undo nuts 920.02.
7. Remove volute casing 102 and casing wear ring 502.
8. Undo nuts 920.12.
9. Remove cover plate 68-3.
7.4.3.3 Dismantling the pump set (MKY)
ü
The notes and steps stated in (
ð
Section 7.4.1, Page 40) to
(
ð
Section 7.4.2, Page 40) have been observed/carried out.
ü
The pump set is kept in a clean and level assembly area.
1. Remove float switch control equipment, if any.
2. Undo screws 900.61 and remove cover plates 81-92.
3. Undo nut 920.62 at gland follower 452.62 and unscrew pipe 710.01 from volute
casing 102.
4. Remove gland follower 452.62, gland packing 461.62 and neck ring 457.
5. Undo nuts 920.02.
6. Remove volute casing 102 with casing wear ring 502.
7. Remove grooved pin 561.02 and take impeller 230 off the shaft.
8. Remove radial bearing 303.03 with bush 545.
9. Undo nuts 920.01.
10. Remove support column 712.01.
CAUTION
Damage to the shaft assembly
Warping of the shaft!
▷
Support the shaft assembly if the shaft is long.
11. For installation depths 1900 mm/2800 mm: Undo the corresponding hexagon
head bolt 901.03 and nut 920.03 and carefully take further support column(s)
712.02/.03 and radial bearings 303.02 and 303.03 (if any) with the respective
bearing bush 545 off the shaft.
12. Loosen nuts 920.60 at the gland follower.
13. Undo nuts 920.61.
14. Remove drive lantern 341 with gasket 400.60 at the lower end of the shaft.
15. Remove gland follower 452.60 and take out discs 550.60 and gland packing
461.60/.61.
16. Undo hexagon head bolts 901.01 and remove the motor.
17. Remove the key.
18. Drive grooved pin 561.01 out of sleeve 520.
Summary of Contents for MK
Page 1: ...Waste Water Condensate and Heat Transfer Fluid Pump MK Installation Operating Manual ...
Page 62: ......
Page 63: ......