8 Trouble-shooting
50 of 64
MK
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB customer service is required.
A
Pump does not start up
B
Motor is overloaded
Motor protection switch trips the pump
C
Pump delivers insufficient flow rate
D
Excessive pump flow rate
E
Vibrations during pump operation
F
Excessive wear on bearings
Table 14:
Trouble-shooting
A B C D E
F Possible cause
Remedy
11)
-
-
✘
-
-
- Wrong direction of rotation
▪
Check the electrical connection of the
pump set and the control system, if
necessary.
-
✘ ✘
-
✘
- Wear of internal components
▪
Replace worn components by new ones.
-
✘
-
✘
-
- System head is lower than specified in the
purchase order.
▪
Re-adjust to duty point by means of the
shut-off valve in the discharge line.
▪
Check whether the impeller could be
turned down.
-
✘ ✘
-
-
- Density or viscosity of fluid handled higher
than stated in purchase order
▪
Contact the manufacturer.
-
✘
-
-
-
- Gland follower over-tightened or cocked
▪
Tighten gland follower correctly.
-
✘ ✘
-
-
- Motor is running on two phases only.
▪
Check the electrical cable connections.
▪
Replace the defective fuse.
✘
-
-
-
-
- Motor is not running because of lack of
voltage.
▪
Check electrical connections.
▪
Notify the energy supply company.
-
✘
-
-
-
- Switchgear, control unit or overcurrent relay
defective.
Check and replace, if necessary.
▪
Check and replace defective components.
-
-
✘
-
-
- Pump delivers against an excessively high
pressure.
▪
Re-adjust to duty point.
▪
Check system for impurities.
▪
Fit larger impeller.
12)
▪
Increase the speed (turbine, I.C. engine)
-
✘ ✘
-
✘
- Supply line or impeller clogged
▪
Remove deposits in the pump and/or
piping.
-
✘ ✘
-
✘
- Insufficient inflow
▪
Check suction openings/screen of the
volute casing for dirt accumulation.
11)
Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
12)
Contact KSB.