5 Installation at Site
25 of 76
Etaprime L
NOTE
Use a filter with laid-in wire mesh of 0.5 mm x 0.25 mm (mesh size x wire diameter)
made of corrosion-resistant material.
Use a filter with a filter area three times the cross-section of the piping.
Conical filters have proved suitable.
2.
Connect the pump nozzles to the piping.
Observe the distances stated above (see illustration: Distances of suction and
discharge lines).
CAUTION
Aggressive flushing and pickling agents
Damage to the pump!
▷
Match the cleaning operation mode and duration for flushing and pickling
service to the casing and seal materials used.
5.4.2 Permissible forces and moments at the pump nozzles
[+]
F
z
F
y
F
x
F
x
F
y
F
z
F
x
F
y
F
z
M
z
M
y
M
x
Fig. 9:
Forces and moments
at the pump nozzles
The data on forces and moments apply to static pipelines only. The values are only
applicable if the pump is installed on a baseplate and bolted to a rigid and level
foundation.
Table 8:
Forces and moments at the pump nozzles for casing material G (EN-GJL-250/A48CL35B)
Size
Suction nozzle
Discharge nozzle
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
[mm]
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm] [mm]
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
25-25-100
25
300
265
250
472
315
210
245
25
265
250
300
472
315
210
245
32-32-120
32
370
320
300
574
390
265
300
32
320
300
370
574
390
265
300
40-40-110
40
450
400
350
696
450
320
370
40
400
350
450
696
450
320
370
40-40-140
40
450
400
350
696
450
320
370
40
400
350
450
696
450
320
370
50-50-130
50
580
530
470
916
500
350
400
50
530
470
580
916
500
350
400
50-50-160
50
580
530
470
916
500
350
400
50
530
470
580
916
500
350
400
65-65-150
65
740
650
600
1153
530
390
420
65
650
600
740
1153
530
390
420
65-65-180
65
740
650
600
1153
530
390
420
65
650
600
740
1153
530
390
420
80-80-170
80
880
790
720
1385
560
400
460
80
790
720
880
1385
560
400
460
80-80-190
80
880
790
720
1385
560
400
460
80
790
720
880
1385
560
400
460
80-80-200
80
880
790
720
1385
560
400
460
80
790
720
880
1385
560
400
460
100-100-240.1
100
1180 1050
950
1843
620
440
510
100
1050
950
1180 1843
620
440
510
100-100-240
100
1180 1050
950
1843
620
440
510
100
1050
950
1180 1843
620
440
510
125-125-260
125
1400 1250 1120 2186
740
530
670
125
1250 1120 1400 2186
740
530
670
Table 9:
Forces and moments at the pump nozzles for casing material C (1.4408/ A743 GR CF8M)
Size
Suction nozzle
Discharge nozzle
DN
[mm]
Fx
Fy
Fz
∑
F
Mx
My
Mz
DN
Fx
Fy
Fz
∑
F
Mx
My
Mz
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm] [mm]
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
32-32-120
32
780
650
500
1132
415
230
320
32
650
500
780
1132
415
230
320
40-40-110
40
970
780
650
1404
500
280
410
40
780
650
970
1404
500
280
410
40-40-140
40
970
780
650
1404
500
280
410
40
780
650
970
1404
500
280
410
Summary of Contents for Etaprime L
Page 1: ...Self priming Pump Etaprime L Installation Operating Manual...
Page 74: ......
Page 75: ......