3 Transport/Temporary Storage/Disposal
9 of 44
EA-C
3 Transport/Temporary Storage/Disposal
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and
notify KSB or the supplying dealer and the insurer about the damage in writing
immediately.
3.2 Transport
CAUTION
Impacts against the coupling when placing in a horizontal or vertical position
Damage to the coupling!
▷
Place a suitable support underneath the coupling half when placing it in a
horizontal or vertical position.
Transport the actuator carefully and in its original packaging. Avoid damaging the
coating.
3.3 Storage/preservation
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken:
Table 3:
Ambient conditions for storage
Ambient condition
Value
Storage temperature
-20 °C to +80 °C
Humidity
5 % to 95 % rH
▪
Well-ventilated
▪
Dry
▪
Dust-free
▪
Shock-free
▪
Vibration-free
3.4 Disposal/recycling
Due to some components, the product is classified as special waste.
1. Dismantle the product.
2. Separate and sort the materials, e.g. by:
- Metals
- Plastics
- Electronic waste
- Greases and other lubricants
3. Dispose of materials in accordance with local regulations or in another
controlled manner. PCBs, power electronics, capacitors and electronic
components are all hazardous waste.
Summary of Contents for EA-C