4 Description
4.1 General description
▪
Submersible mixer
Submersible mixer with self-cleaning propeller for handling municipal or industrial
waste water and sludges, as well as for use in biogas applications.
4.2 Designation
Example: Amamix C 41 3 8 / 3 8 XD C
Table 5: Key to the designation
Code
Description
Amamix
Type series
C
Propeller material, e.g. C = stainless steel
41
Nominal propeller diameter, e.g. 410 mm
3
Number of blades
8
Code for incidence angle of propeller
3
Motor size
8
Number of motor poles
XD
Motor version
C
Casing material, e.g. C = stainless steel
4.3 Name plate
TYPE
No.
Q
P
2
KSB Aktiengesellschaft
67227 Frankenthal
Mat. No: 01232063 ZN 3826 - M 19
TEMP. MAX.
WANING - DO NOT OPEN WHEN ENERGIZED
THERMALLY PROTECTED
a)
b)
°F
lbs
H
Motor
IP 68
SUBM. MAX. 100FT CLASS H
3~
M.-No.
HP
V
Hz
PF
RPM
FLA
LRA
SF
TYPE
No.
Q
P
2
KSB Aktiengesellschaft
67227 Frankenthal
Mat. No: 01080567 ZN 3826 - M 17
TEMP. MAX.
WANING - DO NOT OPEN WHILE ENERGIZED
THERMALLY PROTECTED
MADE IN GEMANY
°F
lbs
H
Motor
IP 68
SUBM. MAX. 100FT CLASS F
3~
M.-No.
HP
V
Hz
PF
RPM
FLA
LRA
SF
FM
XP CLASS I, DIV. 1 GROUPS C&D T
MADE IN GERMANY
APPROVED
1
2
9
10
4
3
5
6
7
8
12
13
14
11
15
16
17
19
18
AMAMIX C 4138/38 UDG
9971143406/000900
104
440
DKN 160.4-8
3.4
710
12.1
88
0.69
460
60
123456
AMAMIX C 4138/38 XDG
9971143406/000900
104
440
DKN 160.4-8
3.4
710
12.1
88
0.69
460
60
123456
1.15
2010
2010
ft
1.15
Fig. 1: Name plate (example) a) for standard submersible mixer, b) for explosion-
proof submersible mixer
1
Designation
2
KSB order number
3
Maximum fluid and ambient
temperature
4
Enclosure
5
Motor type
6
Rated power
7
Rated speed
8
Rated voltage
9
Rated current
10
Year of construction
11
Total weight
12
Maximum submergence
13
Thermal class of winding
insulation
14
Motor number
15
Power factor at design point
16
Rated frequency
17
Service factor
18
Starting current
19
Marking for explosion-proof
submersible mixers
4.4 Design details
Design
▪
Fully floodable submersible mixer
▪
Horizontal installation
4 Description
Amamix