7 Servicing/Maintenance
74 of 126
Amacan K
1579.807/07-EN
5. Fasten cable gland 834.02 with socket head cap screws 914.05 and secure the
screwed connection with Loctite 243.
6. Connect plug 81-2 to the control cable cores.
Fastening the cover plate to
the bail
ü
The motor housing cover has been removed, placed down and protected against
rolling off.
ü
The power cable has been fitted as described in this manual.
ü
The control cable has been fitted as described in this manual.
1. Insert the power and control cables with cable protector 81-97 into cover plate
82-11 or 68-3.02.
2. Fasten the cover plate to the bail.
7.7.3 Fitting the motor housing cover
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe the EN 61557 regulations as well as any regional regulations.
571
811
80-1
a
b
812
914.01
903.51
811
80-1
550.23
920.23
920.24
932.23
835
81-2
A
A
A - A
L
243
Fig. 41:
Fitting the motor housing cover
a
Alignment grooves of motor housing cover 812
b
Alignment groove of motor housing 811