7 Servicing/Maintenance
71 of 126
Amacan K
1579.807/07-EN
7.6.6.2 Removing the cable gland and connection cable
571
68-3.02
(82-11)
914.05
834.02
914.04
834.01
812
81-18.03
901.20
932.20
81-29.03
A - A
A
A
Fig. 39:
Removing the connection cable and cable gland
Removing the power cable
ü
The motor housing cover has been removed, placed down and protected against
rolling off.
1. Remove cover plate 82-11 or 68-3.02 from bail 571. Take out the cable gland
834.01/02 needing to be replaced.
2. Disconnect the earth connector on the inside of motor housing cover 812. If a
shielded cable is used, disconnect the shield as well.
3. Undo screws 914.04 at cable gland 834.01.
4. Pull cable gland 834.01 out of the centring seat in motor housing cover 812.
Removing the control cable
ü
The motor housing cover has been removed, placed down and protected against
rolling off.
1. Disconnect the cores of the control cable from plug 81-2.
2. Undo screws 914.05 at cable gland 834.02.
3. Pull cable gland 834.02 out of the centring seat in motor housing cover 812.
NOTE
Keeping a record of the core identification and lengths is recommended. This will
facilitate installing the replacement cable gland.
7.7 Reassembling the pump set
7.7.1 General information/Safety regulations
DANGER
Wrong screws/bolts
Explosion hazard!
▷
Always use the original screws/bolts for assembling an explosion-proof pump
set.
▷
Never use screws/bolts of different dimensions or of a lower property class.