If you are using batteries as your source of power, remove the 6 phillips screws on the battery 

cover located on the front of the control unit.  Install the (4) AA Alkaline batteries that are 

included.  It is very important to make sure each battery is placed in the proper direction.  

Replace battery cover and screws. 

 

ƒ

If you are using the optional AC adapter as your source of power, you will need to remove the 

rubber plug on the control unit.  Insert the small plug from the transformer into the control 

unit.  Plug transformer into wall outlet using appropriate caution

 

ƒ

If using optional Hydro Generator please follow directions included with the device.

 

ƒ

Turn on the hot and cold wall water stops to supply the faucet with water.   

Check all connections for leaks.

 

ƒ

Adjust mixing valve to the temperature desired.

STEP 4 • Power Connection

Control Module Settings

STEP 5 • Water Connection

INSTALLATION (con’t)

 

ƒ

Shut Off Delay: 1s, 10s, 15s

 

ƒ

Auto Flush: (15s flush after every 12 inactive hours) ON or OFF

 

ƒ

Auto Time Out: 15s, 20s, 25s, 30s, 45s, 1m, 2m, 10m

 

ƒ

Shut Off Delay: 1 sec

 

ƒ

Auto Flush: OFF

 

ƒ

Auto Time Out: 15 sec

 

ƒ

Hold for 10s

 

ƒ

LED on sensor will turn on & stay lit

 

ƒ

Let go of button

 

ƒ

LED light will turn off

 

ƒ

Place hand/object at desired distance

 

ƒ

Make sure the LED is flashing

 

ƒ

If the LED is not flashing, you have a  

faulty control box or you are out of range

 

ƒ

Hold hand/object at desired distance for 5s

 

ƒ

LED will have one last long flash, settings are 

saved

 

ƒ

ON will flush a full cycle if not in use 

for 12 hours

 

ƒ

ONE CYCLE is based on Auto-Cutoff 

time setting

 

ƒ

0: Delayed shut-off is 1s

 

ƒ

1: Delayed shut-off is 10s

 

ƒ

2: Delayed shut-off is 15s

 

ƒ

0: 15s max

 

ƒ

1: 20s max

 

ƒ

2: 25s max

 

ƒ

3: 30s max

 

ƒ

4: 45s max

 

ƒ

5: 1m max

 

ƒ

6: 2m max

 

ƒ

7: 10m max

Optional Settings:

Factory Default Settings:

Flow controls can be found inside control module after removing the battery cover.

Sensor Setup  

Button / Reset Button Procedure

Auto Flush Switch (Default setting: OFF)

Delayed Shut-Off  

(Time before water shuts off  

after hands leave the faucet)

Auto-Cutoff (Maximum time  

water can flow for one cycle)

A

D

B

C

0

1

2

3

4

5

6

7 8 9

0

1

2

3

A

B

C

D

side of the hot water supply line to the hot side of the mixing valve and tighten properly and do 

the same for the cold supply line.  Do not overtighten.  Do not use thread sealant.

Summary of Contents for Royal 16-190

Page 1: ...1 ELECTRONIC SENSOR FAUCET INSTRUCTION MANUAL Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com...

Page 2: ...512 2 Control Module 16 198 3 Mechanical Mixing Valve 16 402L 4 Hot Cold Supply Hoses 16 510 5 AC Adapter optional 16 199 6 Thermostatic Mixing Valve optional 16 405L 7 Replacement Filter 16 187 8 Hy...

Page 3: ...o Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with...

Page 4: ...2 1 3 3 3 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with Cable 16 506 3 4 Deck Plate optional 16 189 No Part Model 1 1 0 GPM Outlet 22 577L 2 Convex Sensor with Cable 16 506 3 4 Deck Plat...

Page 5: ...Wall Mount with 4 1 2 Double Bend Spout Satin Finish 2 1 1 Model 16 675 Single Hole Wall Mount Satin Finish 1 1 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1...

Page 6: ...all plumbing and electrical in accordance with national local codes and regulations Use precaution when connecting optional AC adapter to power source Power Working Pressure Temperature Range Sensing...

Page 7: ...s shown in below MOUNT ON SURFACE UP TO 1 THICK STEP 1 INSTALL FAUCET ASSEMBLY INSTALLATION Model 16 192 Mounting Surface Washer Nut Brass Elbow Model 16 649 Base Gasket Mounting Surface Lock Washer N...

Page 8: ...et Mounting Surface Lock Washer Nut Model 16 197 Base Gasket Mounting Surface Lock Washer Nut Model 16 654 Base Gasket Mounting Surface Washer Nut INSTALLATION con t Model 16 650 Base Gasket Mounting...

Page 9: ...9 Model 16 675 INSTALLATION con t Model 16 670 Mounting Surface Mounting Surface Washer Washer Nut Nut Brass Elbow Brass Elbow...

Page 10: ...onnector and gently tighten Do not overtighten Remove the 2 small stainless steel screens inside small plastic bag and place one inside each of the 2 water lines Connect the compression fitting with t...

Page 11: ...m 2m 10m Shut Off Delay 1 sec Auto Flush OFF Auto Time Out 15 sec Hold for 10s LED on sensor will turn on stay lit Let go of button LED light will turn off Place hand object at desired distance Make s...

Page 12: ...n After washing rinse and wipe down with a soft towel Do not use any abrasive cleaners as they will corrode the chrome finish Be sure to keep the eye sensor clear of chemical cleaners to ensure functi...

Page 13: ...s in Hot Cold water supply line stainless screen filter Remedy 1 The inline filter located below the black plastic cap may be clogged Turn off water supply and remove the black plastic cap and clean t...

Page 14: ...CONDITIONS AND EXCLUSIONS A Warranty Subject to the conditions and exclusions set forth below Seller warrants to Buyer i that Seller holds and will pass marketable title to the goods sold hereunder ii...

Page 15: ...TERMS The method of shipment and carrier shall be determined by Seller unless Buyer shall have specified a method of shipment and carrier more than ten 10 days prior to scheduled shipment Title and a...

Page 16: ...16 Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com OTHER GREAT PRODUCTS BY KROWNE...

Reviews: