background image

10

COLD

HOT

IN

OUT

STEP 2 • Install Mechanical Mixing Valve

Install Mechanical Mixing Valve into inlet location #1 on the Control Module, which has a  

compression fitting.  Do not use thread sealant and do not overtighten.  The Control 

Module is to be mounted to a wall and the Mechanical Mixing Valve must be straight 

as per photo below.  Pick mounting location that will allow the supply lines and cable 

to have slack to prevent strain.  Mount Control Module on wall using mounting screws 

and plastic anchors provided.

Install the spout supply line from supply inlet which has compression fittings, onto the 

spout inlet and tighten properly.  Do not overtighten.  Do not use thread sealant.
Install the sensor cable onto the control unit.  It is very important to match up the 

white arrows when connecting the sensor cable to the fitting on the control unit.  

Gently push it into place as forcing it can damage the pins.  Slide chrome cap over 

black connector and gently tighten.  Do not overtighten.
Remove the 2 small stainless steel screens inside small plastic bag and place one 

inside each of the 2 water lines.  Connect the compression fitting with the screen 

onto the wall supply stops(not included) and do the same for the other water line.  

This screen will prevent debris from going inside the control valve.  Connect the other 

STEP 3 • Install Sensor Cables and Supply Lines

 

ƒ

Install the spout water supply line, which has a compression fitting, onto the faucet body and 

tighten properly.  Do not overtighten.  Do not use thread sealant.

 

ƒ

On wall mount models you must install brass elbow on spout inlet before installing spout water 

supply line.  Do not overtighten.  Do not use thread sealant.

 

ƒ

Feed the sensor cable and supply inlet through the hole & mount faucet body onto surface.   

Do not overtighten.  Do not use thread sealant.

Sensor Cable

Optional AC 

adapter

Optional Thermostatic 

Mixing Valve

Mechanical  

Mixing Valve

Hot & Cold

Water Lines

INSTALLATION (con’t)

1

2

2

1

4

3

3

4

Spout Supply

Filter

Control Module

Note: Refer to below diagram for step by step installation.

stainless steel screens

Summary of Contents for Royal 16-190

Page 1: ...1 ELECTRONIC SENSOR FAUCET INSTRUCTION MANUAL Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com...

Page 2: ...512 2 Control Module 16 198 3 Mechanical Mixing Valve 16 402L 4 Hot Cold Supply Hoses 16 510 5 AC Adapter optional 16 199 6 Thermostatic Mixing Valve optional 16 405L 7 Replacement Filter 16 187 8 Hy...

Page 3: ...o Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with...

Page 4: ...2 1 3 3 3 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with Cable 16 506 3 4 Deck Plate optional 16 189 No Part Model 1 1 0 GPM Outlet 22 577L 2 Convex Sensor with Cable 16 506 3 4 Deck Plat...

Page 5: ...Wall Mount with 4 1 2 Double Bend Spout Satin Finish 2 1 1 Model 16 675 Single Hole Wall Mount Satin Finish 1 1 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1...

Page 6: ...all plumbing and electrical in accordance with national local codes and regulations Use precaution when connecting optional AC adapter to power source Power Working Pressure Temperature Range Sensing...

Page 7: ...s shown in below MOUNT ON SURFACE UP TO 1 THICK STEP 1 INSTALL FAUCET ASSEMBLY INSTALLATION Model 16 192 Mounting Surface Washer Nut Brass Elbow Model 16 649 Base Gasket Mounting Surface Lock Washer N...

Page 8: ...et Mounting Surface Lock Washer Nut Model 16 197 Base Gasket Mounting Surface Lock Washer Nut Model 16 654 Base Gasket Mounting Surface Washer Nut INSTALLATION con t Model 16 650 Base Gasket Mounting...

Page 9: ...9 Model 16 675 INSTALLATION con t Model 16 670 Mounting Surface Mounting Surface Washer Washer Nut Nut Brass Elbow Brass Elbow...

Page 10: ...onnector and gently tighten Do not overtighten Remove the 2 small stainless steel screens inside small plastic bag and place one inside each of the 2 water lines Connect the compression fitting with t...

Page 11: ...m 2m 10m Shut Off Delay 1 sec Auto Flush OFF Auto Time Out 15 sec Hold for 10s LED on sensor will turn on stay lit Let go of button LED light will turn off Place hand object at desired distance Make s...

Page 12: ...n After washing rinse and wipe down with a soft towel Do not use any abrasive cleaners as they will corrode the chrome finish Be sure to keep the eye sensor clear of chemical cleaners to ensure functi...

Page 13: ...s in Hot Cold water supply line stainless screen filter Remedy 1 The inline filter located below the black plastic cap may be clogged Turn off water supply and remove the black plastic cap and clean t...

Page 14: ...CONDITIONS AND EXCLUSIONS A Warranty Subject to the conditions and exclusions set forth below Seller warrants to Buyer i that Seller holds and will pass marketable title to the goods sold hereunder ii...

Page 15: ...TERMS The method of shipment and carrier shall be determined by Seller unless Buyer shall have specified a method of shipment and carrier more than ten 10 days prior to scheduled shipment Title and a...

Page 16: ...16 Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com OTHER GREAT PRODUCTS BY KROWNE...