MANUALLY OPERATING THE FAUCET.
The faucet can be manually operated without placing
hands in front of the sensor. To do this, remove the front battery cover. Press on the small button
for 10 seconds in order to begin the water flow. Press again to cease the water flow. If the faucet
is left on, it will automatically turn off in a minute.
ELECTRONIC EYE CLEANING.
The electronic eye should be cleaned with a cloth and warm water.
FILTER MAINTENANCE.
We recommend cleaning the filter every 6 months or sooner
depending on water conditions.
THINGS TO KNOW
Place your hands under the faucet. The water will flow for 15 seconds if user’s hands are
within the sensor’s range. When hands are removed the water flow should stop.
Keep electronic eye cover clean for optimal performance
A red flashing LED light indicates the faucet has low battery power
A solid LED with no water flow indicates the batteries are dead and need replacing
New AA alkaline batteries should provide upwards of 500,000 on/off cycles
Use soap and warm water to keep faucet clean. After washing, rinse and wipe down with a soft
towel. Do not use any abrasive cleaners as they will corrode the chrome finish. Be sure to keep
the eye sensor clear of chemical cleaners to ensure functionality.
Clean aerator/outlet and in-line water filter (located inside black cap) yearly
Based on usage, replace with AA alkaline batteries (provide upwards of 500,000 on/off cycles)
OPERATING THE FAUCET
MAINTENANCE
Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
Note: After identifying the issue, turn-off water supply before proceeding with repair
TROUBLESHOOTING
No water flow when activated
Possible Causes
a. Power supply Failure (Batteries)
b. Power Supply Failure (AC Adapter or tripped circuit breaker)
c. Water supply is turned off
d. Clogged inline water filter or aerator/outlet
e. Sensor not working
f. Control Module not working
Remedy
1. Verify there is not a power supply failure. If using batteries remove the front battery
cover and replace with new batteries. If using optional AC adapter, ensure that adapter is
plugged in and that the ac outlet has power
2. The water supply stops may be closed. Open the supply stops for water flow
continued on next page