background image

12

MANUALLY OPERATING THE FAUCET.  

The faucet can be manually operated without placing 

hands in front of the sensor.  To do this, remove the front battery cover. Press on the small button  

for 10 seconds in order to begin the water flow.  Press again to cease the water flow.  If the faucet 

is left on, it will automatically turn off in a minute.

ELECTRONIC EYE CLEANING.  

The electronic eye should be cleaned with a cloth and warm water.

FILTER MAINTENANCE.  

We recommend cleaning the filter every 6 months or sooner  

depending on water conditions.

THINGS TO KNOW

Place your hands under the faucet. The water will flow for 15 seconds if user’s hands are  

 

within the sensor’s range.  When hands are removed the water flow should stop.

 

ƒ

Keep electronic eye cover clean for optimal performance

 

ƒ

 A red flashing LED light indicates the faucet has low battery power

 

ƒ

 A solid LED with no water flow indicates the batteries are dead and need replacing

 

ƒ

New AA alkaline batteries should provide upwards of 500,000 on/off cycles

Use soap and warm water to keep faucet clean.  After washing, rinse and wipe down with a soft 

towel.  Do not use any abrasive cleaners as they will corrode the chrome finish.  Be sure to keep 

the eye sensor clear of chemical cleaners to ensure functionality.  

 

ƒ

Clean aerator/outlet and in-line water filter (located inside black cap) yearly

 

ƒ

Based on usage, replace with AA alkaline batteries (provide upwards of 500,000 on/off cycles)

OPERATING THE FAUCET

MAINTENANCE

Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Note: After identifying the issue, turn-off water supply before proceeding with repair

TROUBLESHOOTING

No water flow when activated

Possible Causes 

a.  Power supply Failure (Batteries) 

b.  Power Supply Failure (AC Adapter or tripped circuit breaker) 

c.  Water supply is turned off  

d.  Clogged inline water filter or aerator/outlet 

e.  Sensor not working 

f.  Control Module not working

Remedy

1.  Verify there is not a power supply failure.  If using batteries remove the front battery  

 

cover and replace with new batteries.  If using optional AC adapter, ensure that adapter is  

 

plugged in and that the ac outlet has power

2.  The water supply stops may be closed.  Open the supply stops for water flow

continued on next page

Summary of Contents for Royal 16-190

Page 1: ...1 ELECTRONIC SENSOR FAUCET INSTRUCTION MANUAL Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com...

Page 2: ...512 2 Control Module 16 198 3 Mechanical Mixing Valve 16 402L 4 Hot Cold Supply Hoses 16 510 5 AC Adapter optional 16 199 6 Thermostatic Mixing Valve optional 16 405L 7 Replacement Filter 16 187 8 Hy...

Page 3: ...o Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with...

Page 4: ...2 1 3 3 3 No Part Model 1 1 0 GPM Outlet 22 576L 2 Convex Sensor with Cable 16 506 3 4 Deck Plate optional 16 189 No Part Model 1 1 0 GPM Outlet 22 577L 2 Convex Sensor with Cable 16 506 3 4 Deck Plat...

Page 5: ...Wall Mount with 4 1 2 Double Bend Spout Satin Finish 2 1 1 Model 16 675 Single Hole Wall Mount Satin Finish 1 1 No Part Model 1 1 0 GPM Outlet 22 576L 2 Flat Sensor with Cable 16 505 No Part Model 1...

Page 6: ...all plumbing and electrical in accordance with national local codes and regulations Use precaution when connecting optional AC adapter to power source Power Working Pressure Temperature Range Sensing...

Page 7: ...s shown in below MOUNT ON SURFACE UP TO 1 THICK STEP 1 INSTALL FAUCET ASSEMBLY INSTALLATION Model 16 192 Mounting Surface Washer Nut Brass Elbow Model 16 649 Base Gasket Mounting Surface Lock Washer N...

Page 8: ...et Mounting Surface Lock Washer Nut Model 16 197 Base Gasket Mounting Surface Lock Washer Nut Model 16 654 Base Gasket Mounting Surface Washer Nut INSTALLATION con t Model 16 650 Base Gasket Mounting...

Page 9: ...9 Model 16 675 INSTALLATION con t Model 16 670 Mounting Surface Mounting Surface Washer Washer Nut Nut Brass Elbow Brass Elbow...

Page 10: ...onnector and gently tighten Do not overtighten Remove the 2 small stainless steel screens inside small plastic bag and place one inside each of the 2 water lines Connect the compression fitting with t...

Page 11: ...m 2m 10m Shut Off Delay 1 sec Auto Flush OFF Auto Time Out 15 sec Hold for 10s LED on sensor will turn on stay lit Let go of button LED light will turn off Place hand object at desired distance Make s...

Page 12: ...n After washing rinse and wipe down with a soft towel Do not use any abrasive cleaners as they will corrode the chrome finish Be sure to keep the eye sensor clear of chemical cleaners to ensure functi...

Page 13: ...s in Hot Cold water supply line stainless screen filter Remedy 1 The inline filter located below the black plastic cap may be clogged Turn off water supply and remove the black plastic cap and clean t...

Page 14: ...CONDITIONS AND EXCLUSIONS A Warranty Subject to the conditions and exclusions set forth below Seller warrants to Buyer i that Seller holds and will pass marketable title to the goods sold hereunder ii...

Page 15: ...TERMS The method of shipment and carrier shall be determined by Seller unless Buyer shall have specified a method of shipment and carrier more than ten 10 days prior to scheduled shipment Title and a...

Page 16: ...16 Krowne Metal Corporation 100 Haul Road Wayne NJ 07470 Toll Free 800 631 0442 customerservice krowne com krowne com OTHER GREAT PRODUCTS BY KROWNE...

Reviews: