VII - 5
Maintenance
7.5.1 Adjusting the Sensors
Namur sensor d = 12 mm
The dimension between the encoder (2) and the sensor
(1) must be “a“ = 2 mm.
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension “a” = 2 mm is reached.
• Tighten the nuts again.
Namur sensor d = 30 mm
The dimension between the encoder (2) and the sensor
(1) must be “a” = 5 mm.
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension “a” = 5 mm is reached.
• Tighten the nuts again.
a
BPXC0172
2
1
3
a
BP-VFS-088-1
2
1
3
Reed sensor
The dimension between the encoder (2) and the sensor
(1) must be “a” = 5 mm.
Setting
• Loosen the nuts on either side of the sensor.
• Turn the nuts until dimension “a” = 5 mm is reached.
• Tighten the nuts again.
a
TR000040
2
1
3
Summary of Contents for Titan 6/50 GL
Page 4: ...Foreword ...
Page 8: ...Contents A1 3 Assembling the superstructure A 7 A2 Electrical circuit diagram A 10 ...
Page 12: ...I 4 General information ...
Page 17: ...II 5 Safety ...
Page 24: ...II 12 Safety ...
Page 41: ...III 17 Operation KDW03210 1 Arrest the short cut loading wagon by applying the parkingbrake 1 ...
Page 42: ...III 18 Operation ...
Page 80: ...IV 38 Comfort Control Unit ...
Page 86: ...VI 4 Hydraulic system 6 2 3 Hydraulic unit standard ...
Page 87: ...VI 5 Hydraulic system 6 2 4 Hydraulic unit operator friendly ...
Page 90: ...VI 8 Hydraulic system ...
Page 110: ...VIII 2 Overwintering ...
Page 112: ...IX 2 Recommissioning ...
Page 114: ...X 2 Faults causes and removal ...
Page 133: ...A 19 Appendix ...