Maintenance
83
Pos : 42.34 /Ü bersc hriften/Ü berschrif ten 3/ A-E/ Einst ellung der Sensor en @ 0\mod_1199962173428_78. doc x @ 37635 @ 3 @ 1
11.10.1
Adjusting the Sensors
Pos : 42.35 / BA/ War tung/Sensor en/Namurs ens or d = 30 mm a= 5mm @ 0\ mod_1199962520100_78.doc x @ 37673 @ 4 @ 1
11.10.1.1
Namur sensor d = 30 mm
a
BPXC0172
2
1
3
Figure 51
The dimension between the encoder (2) and the sensor (1) must be "a" = 5 mm .
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 5 mm is reached.
•
Tighten the nuts again.