![Krone Swadro 1000 Original Operating Instruction Download Page 43](http://html1.mh-extra.com/html/krone/swadro-1000/swadro-1000_original-operating-instruction_2004826043.webp)
Medium Control Unit
43
Pos : 21.39 /Ü bersc hriften/Ü berschrif ten 2/ P-T/Stör ung en - Ursachen und Behebung @ 2\ mod_1203325826011_78. doc x @ 65688 @ 2 @ 1
6.15
Malfunctions - Causes and Remedies
Pos : 21.40 / BA/I nf o-Cent er/Schwader/ Bedi eneinheit - M edi um/ Swadro 1000/St ör ungen_Ursac he_Behebung @ 2\ mod_1203325023621_78.doc x @ 65669 @ @ 1
No.
Description
Possible cause
Remedy
11
Over/under
voltage
Tractor battery defective
Check battery
Tractor dynamo defective/too weak.
Check dynamo
12-V power supply too weak on the tractor
side or not correctly connected with the
battery.
Connect the KRONE connection cable to
the tractor battery
13
CAN error
The CAN bus was interrupted between
the control unit and the machine > loose
connection to display screen.
Check the display line.
14
Incorrect
terminal
Connection to incorrect terminal.
Use the terminal appropriate to the
swather type.
15
Incorrect
terminal
software
Terminal software and job computer not
compatible
Use correct software.
16
Control unit key
defective
Key sticks when turned on.
Check keys.
21
Sensor error
Broken cable / short circuit in a sensor.
Check sensors
Pos : 21.41 / BA/---------------Seitenumbr uc h---------------- @ 0\ mod_1196175311226_0.doc x @ 4165 @ @ 1