Maintenance
232
Pos: 29.25 /Überschriften/Überschriften 3/A-E/Einstellung der Sensoren @ 0\mod_1199962173428_78.doc @ 37635
13.5.1
Adjusting the Sensors
Pos: 29.26 /BA/Wartung/Sensoren/Namursensor d = 12 mm @ 0\mod_1199962247038_78.doc @ 37654
13.5.1.1
Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 210
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 2 mm
is reached.
•
Tighten the nuts again.
Pos: 29.27 /BA/Wartung/Sensoren/Namursensor d = 18 mm @ 55\mod_1292240781796_78.doc @ 518322
13.5.1.2
Namur sensor d = 18 mm
a
BP-VFS-088-1
2
1
3
Fig. 211
The dimension between the encoder (2) and the sensor (1)
must
be "a" = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension
"a" = 2 mm
is reached.
•
Tighten the nuts again.
Pos: 29.28 /BA/Wartung/Sensoren/Sensor Motor Mitte @ 55\mod_1292241661406_78.doc @ 518404
The Namur sensor d = 18 mm records the data for position servomotor centre.
Pos: 29.29 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165