Settings
221
Pos: 27.51 /BA/Einstellungen/Rundballenpresse/Zentrale Kettenschmierung Öl prüfen @ 54\mod_1291810809890_78.doc @ 516099
RP100007_1
3
2
1
4
Fig. 200
•
Depending on consumption, check the oil supply in the container and top off if necessary.
If the lubricant container is empty, the central chain lubrication system needs to be bled:
•
Top up the reservoir with oil.
•
Remove the container hose (4) of the pump and wait until oil is leaking.
•
Install the hose to the pump again.
•
Open venting screw (3) and actuate the pump manually until oil flows without bubbles out
of the valve block
.
Note
Replace filter (2) once a year. First remove, empty and then thoroughly clean the tank (1).
Only then replace filter (2). Do not remove filter (2) if oil is present in the filter.
Note
It must absolutely be ensured that no water or dust can enter the tank (1)).