17

English

2.18  Spareparts list

Pos.

Description

Part No.

1

Handle

064499

2

Casing

064468

3

Filter support

064466

4

Main filter E10 / fine dust (dust class M)

064503

4

Main filter H14 / suspended particles (dust class H)

065183

5

Sealing profile, self-locking, made of NBR

053245

6

Fan plate

064467-01

7

Radial fan

100681

8

Fan support

064476-01

9

Filter cassette

064471

10

Pre-filter G4 / coarse dust

064504

11

Lower part

064465-01

12

Differential pressure switch

064505

13

Buzzer

064508

14

Mounting angle

064472-01

15

Locking pin

064511

16

Mounting plate

064469

17

Built-in socket

064509

18

Hours counter

030705

19

Fuse holder for microfuse

006683-01

19a

Fuse holder cover with sealing

006684-01

19b

Fuse

037858

20

Power switch

004723

21

Indicator lamp

064506

22

Wire screwing, metric 20x105 IPON

044898

22a

Counter nut, metric 20x1,5 PVC

063449

23

Quick fastening D20

003764

24

Wheel axle complete

064473

25

Wheel

027186

26

Support

064498

**

without picture
Mounting plate, completely assembled 

064670

Power cable

006450

2.19 

Summary of Contents for LR5300

Page 1: ...Betriebsanleitung Manual LR5300 Mobiler Luftreiniger Mobile air cleaner Originalbetriebsanleitung Manual 064458 01 August 2016...

Page 2: ......

Page 3: ...onszeichnung 8 1 20 Technische Daten 9 1 21 Schaltplan 10 1 22 Zubeh r 11 2 English 12 2 1 General 12 2 2 Scope of delivery 12 2 3 Safety instructions 12 2 4 Designated use 13 2 5 Dimensioning 13 2 6...

Page 4: ...g mit Gefahrstoffen beim Betreiber des Ger tes Der Betreiber hat gegebenenfalls vor Sanierungsbeginn eine Gef hrdungsbeurteilung zu erstellen 1 2 Lieferumfang 1 x Filterger t LR5300 1 x Filterhalter f...

Page 5: ...chsel vom Ger t erfasst und im Filter gebunden Hier bei sollte ein Luftschlauch auf der Ausblasseite oder auf der Ansaugseite so platziert werden dass eine Durchl ftung des gesamten Bereiches gew hrle...

Page 6: ...s durch die Anzeige B und einen Signalton angezeigt Beim Ausl sen dieses Signals sollte der Hauptfilter wie auch die Vorfilter ausge tauscht werden Bitte denken Sie daran gen gend Filtermaterial berei...

Page 7: ...Netzstecker ziehen Nach jedem Gebrauch ist das Ger t gr ndlich zu reinigen Reinigung nur mit Sicherheitssauger und feuchtem Abwischen Druckluft ist nicht erlaubt Hinweis Wurde das Ger t in schadstoffb...

Page 8: ...ng f r brennbare st ube aller staubexplosionsklassen ausgenommen st ube mit extrem niedriger Mindestz ndenergie Me 1 mJ Mindestens S mit B1 zus tzlich Zus tzliche eignung f r brennbare st ube aller st...

Page 9: ...4 11 Unterteil 064465 01 12 Druckw chter 064505 13 Summer 064508 14 Montagewinkel 064472 01 15 Rastbolzen 064511 16 Montageplatte 064469 17 Einbausteckdose 064509 18 Betriebsstundenz hler 030705 19 Si...

Page 10: ...LR5300 8 Deutsch 1 19 Explosionszeichnung 26 25 24 23 22 21 20 18 17 16 15 14 13 12 11 8 10 9 7 6 5 4 3 2 1 19 19b 19a 22a...

Page 11: ...Anschluss V Hz 230 50 Elektrische Leistung kW 0 52 Stromaufnahme A 2 3 Sicherung Ger testeckdose A 6 3 Schalldruckpegel maximal dB A 69 Kabell nge m 3 H he mit eingefahrenem Griff Breite Tiefe mm 900...

Page 12: ...1 h H1 H2 2 1 N Netz PE L1 N PE X1 PE F1 Sicherung Ger testeckdose H1 Filter berwachungslampe H2 Filter berwachungssummer M1 L ftermotor P1 Betriebsstundenz hler S1 Beleuchteter Netzschalter X1 Klemml...

Page 13: ...r G4 Grobstaub 064504 Hauptfilter E10 Feinstaub Staubklasse M 064503 Hauptfilter H14 Schwebstoff Staubklasse H 065183 Ausblasanschluss 305 mm 064475 Schlauchanschluss ansaugseitig 305 mm 064474 Schlau...

Page 14: ...ouble free opera tion all details indicated in this manual regarding installation and commissioning have to be res pected and carried out carefully Read this manual carefully before installation and c...

Page 15: ...Here an air hose should be placed either on the air outlet side or on the air intake side It should be placed in a way to ensure a ventilation of the complete area Particles are to be caught as close...

Page 16: ...g m for E dusts TRGS 900 Example Requested is a 15 fold air change at a room volume of 100 m The necessary air volume is 15 x 100 m thus minimum 1500 m h The Kroll LR5300 brings about 1530 m h when th...

Page 17: ...ncy of the sucked in particles is unknown the filters should be exchanged completely after being used on that site Both filters are to be exchanged in order to avoid bringing the pollutants contaminat...

Page 18: ...LR5300 16 English 2 17 Overview of dust classes...

Page 19: ...part 064465 01 12 Differential pressure switch 064505 13 Buzzer 064508 14 Mounting angle 064472 01 15 Locking pin 064511 16 Mounting plate 064469 17 Built in socket 064509 18 Hours counter 030705 19 F...

Page 20: ...LR5300 18 English 2 20 Exploded view 26 25 24 23 22 21 20 18 17 16 15 14 13 12 11 8 10 9 7 6 5 4 3 2 1 19 19b 19a 22a...

Page 21: ...tion V Hz 230 50 Electrical power kW 0 52 Current consumption A 2 3 Protection of connector A 6 3 Noise level max dB A 69 Cable length m 3 Height with retracted handle width depth mm 900 564 770 Weigh...

Page 22: ...ummer M1 L ftermotor P1 Betriebsstundenz hler S1 Beleuchteter Netzschalter X1 Klemmleiste X2 Anbausteckdose B1 Differenzdruckschalter Filter berwachung P 2 3 B1 2 1 1a S1 LR 5300 M1 Luftreiniger 3 13...

Page 23: ...4 coarse dust 064504 Main filter E10 fine dust dust class M 064503 Main filter H14 suspended particles dust class H 065183 Air outlet connector 305 mm 064475 Air intake connector 305 mm 064474 Hose 30...

Page 24: ...LR5300 22 Konformit t EG declaration of conformity 3 Konformit t EG declaration of conformity...

Page 25: ...23 Notizen Notizen und Besonderheiten...

Page 26: ...24 24 Notizen und Besonderheiten Notizen...

Page 27: ...25 Notizen Notizen und Besonderheiten...

Page 28: ...farrgartenstra e 46 D 71737 Kirchberg Murr Telefon 0049 0 7144 830 200 Telefax 0049 0 7144 830 201 E Mail vertrieb kroll de Internet www kroll de Stand 2017 01 26 12 35 Any use installation maintenanc...

Reviews: