background image

15

English

2.14  Decommissioning

In order to switch off the unit, press the main 

switch (A) and plug off the mains plug. The unit 

has to be cleaned carefully after every single 

use!

Cleaning of the unit only with safety aspirator 

and humid wiping.

Compressed air is not allowed!

Note

If the unit was used in contaminated air, the 

used-up filters have to be packed air-tight and 

to be disposed professionally. The exchange of 

the filters must be done by using personal pro

-

tection devices, especially a suitable breathing 

protection.

Note

2.15 

Changing the filter

The LR5300 uses a two-stage filter system, 

including a pre-filter and a main filter.

Independent from the filter exchange signal, 

both filters are to be exchanged after every sin

-

gle work with harmful substances. If the con-

sistency of the sucked in particles is unknown, 

the filters should be exchanged completely 

after being used on that site. Both filters are 

to be exchanged in order to avoid bringing the 

pollutants (contamination) into clean areas.

Note

Bild 5: 

pre-filter

 

Bild 6: 

main filter 

2.16 

Types of filters

Z-line pre-filter (coarse dust filter) class G4 

according to EN 779

• 

Pre-filter for the main filter

• 

Filter for specifically large dusts up to 3 μm

• 

Degree of separation 85-98 % at 10 μm and 

30-55 % at 1 μm

•  Absorption of coarse dusts

Fine dust filter class E10 according to EN 779

 

Dust class M according EN 60335-2-69, appen-

dix AA

• 

Main filter for fine dusts and particles up to 

1 μm

•  Degree of separation 99,9 %
•  Suitable for restoration areas with strong 

creation of dust

Filter for suspended particles of class H14 accor-

ding to EN 779

Dust class H according to EN 60335-2-69, 

appendix AA

• 

Main filter for fine dusts and particles < 1μm

•  Suitable for restoration areas with strong 

creation of suspended particles

Summary of Contents for LR5300

Page 1: ...Betriebsanleitung Manual LR5300 Mobiler Luftreiniger Mobile air cleaner Originalbetriebsanleitung Manual 064458 01 August 2016...

Page 2: ......

Page 3: ...onszeichnung 8 1 20 Technische Daten 9 1 21 Schaltplan 10 1 22 Zubeh r 11 2 English 12 2 1 General 12 2 2 Scope of delivery 12 2 3 Safety instructions 12 2 4 Designated use 13 2 5 Dimensioning 13 2 6...

Page 4: ...g mit Gefahrstoffen beim Betreiber des Ger tes Der Betreiber hat gegebenenfalls vor Sanierungsbeginn eine Gef hrdungsbeurteilung zu erstellen 1 2 Lieferumfang 1 x Filterger t LR5300 1 x Filterhalter f...

Page 5: ...chsel vom Ger t erfasst und im Filter gebunden Hier bei sollte ein Luftschlauch auf der Ausblasseite oder auf der Ansaugseite so platziert werden dass eine Durchl ftung des gesamten Bereiches gew hrle...

Page 6: ...s durch die Anzeige B und einen Signalton angezeigt Beim Ausl sen dieses Signals sollte der Hauptfilter wie auch die Vorfilter ausge tauscht werden Bitte denken Sie daran gen gend Filtermaterial berei...

Page 7: ...Netzstecker ziehen Nach jedem Gebrauch ist das Ger t gr ndlich zu reinigen Reinigung nur mit Sicherheitssauger und feuchtem Abwischen Druckluft ist nicht erlaubt Hinweis Wurde das Ger t in schadstoffb...

Page 8: ...ng f r brennbare st ube aller staubexplosionsklassen ausgenommen st ube mit extrem niedriger Mindestz ndenergie Me 1 mJ Mindestens S mit B1 zus tzlich Zus tzliche eignung f r brennbare st ube aller st...

Page 9: ...4 11 Unterteil 064465 01 12 Druckw chter 064505 13 Summer 064508 14 Montagewinkel 064472 01 15 Rastbolzen 064511 16 Montageplatte 064469 17 Einbausteckdose 064509 18 Betriebsstundenz hler 030705 19 Si...

Page 10: ...LR5300 8 Deutsch 1 19 Explosionszeichnung 26 25 24 23 22 21 20 18 17 16 15 14 13 12 11 8 10 9 7 6 5 4 3 2 1 19 19b 19a 22a...

Page 11: ...Anschluss V Hz 230 50 Elektrische Leistung kW 0 52 Stromaufnahme A 2 3 Sicherung Ger testeckdose A 6 3 Schalldruckpegel maximal dB A 69 Kabell nge m 3 H he mit eingefahrenem Griff Breite Tiefe mm 900...

Page 12: ...1 h H1 H2 2 1 N Netz PE L1 N PE X1 PE F1 Sicherung Ger testeckdose H1 Filter berwachungslampe H2 Filter berwachungssummer M1 L ftermotor P1 Betriebsstundenz hler S1 Beleuchteter Netzschalter X1 Klemml...

Page 13: ...r G4 Grobstaub 064504 Hauptfilter E10 Feinstaub Staubklasse M 064503 Hauptfilter H14 Schwebstoff Staubklasse H 065183 Ausblasanschluss 305 mm 064475 Schlauchanschluss ansaugseitig 305 mm 064474 Schlau...

Page 14: ...ouble free opera tion all details indicated in this manual regarding installation and commissioning have to be res pected and carried out carefully Read this manual carefully before installation and c...

Page 15: ...Here an air hose should be placed either on the air outlet side or on the air intake side It should be placed in a way to ensure a ventilation of the complete area Particles are to be caught as close...

Page 16: ...g m for E dusts TRGS 900 Example Requested is a 15 fold air change at a room volume of 100 m The necessary air volume is 15 x 100 m thus minimum 1500 m h The Kroll LR5300 brings about 1530 m h when th...

Page 17: ...ncy of the sucked in particles is unknown the filters should be exchanged completely after being used on that site Both filters are to be exchanged in order to avoid bringing the pollutants contaminat...

Page 18: ...LR5300 16 English 2 17 Overview of dust classes...

Page 19: ...part 064465 01 12 Differential pressure switch 064505 13 Buzzer 064508 14 Mounting angle 064472 01 15 Locking pin 064511 16 Mounting plate 064469 17 Built in socket 064509 18 Hours counter 030705 19 F...

Page 20: ...LR5300 18 English 2 20 Exploded view 26 25 24 23 22 21 20 18 17 16 15 14 13 12 11 8 10 9 7 6 5 4 3 2 1 19 19b 19a 22a...

Page 21: ...tion V Hz 230 50 Electrical power kW 0 52 Current consumption A 2 3 Protection of connector A 6 3 Noise level max dB A 69 Cable length m 3 Height with retracted handle width depth mm 900 564 770 Weigh...

Page 22: ...ummer M1 L ftermotor P1 Betriebsstundenz hler S1 Beleuchteter Netzschalter X1 Klemmleiste X2 Anbausteckdose B1 Differenzdruckschalter Filter berwachung P 2 3 B1 2 1 1a S1 LR 5300 M1 Luftreiniger 3 13...

Page 23: ...4 coarse dust 064504 Main filter E10 fine dust dust class M 064503 Main filter H14 suspended particles dust class H 065183 Air outlet connector 305 mm 064475 Air intake connector 305 mm 064474 Hose 30...

Page 24: ...LR5300 22 Konformit t EG declaration of conformity 3 Konformit t EG declaration of conformity...

Page 25: ...23 Notizen Notizen und Besonderheiten...

Page 26: ...24 24 Notizen und Besonderheiten Notizen...

Page 27: ...25 Notizen Notizen und Besonderheiten...

Page 28: ...farrgartenstra e 46 D 71737 Kirchberg Murr Telefon 0049 0 7144 830 200 Telefax 0049 0 7144 830 201 E Mail vertrieb kroll de Internet www kroll de Stand 2017 01 26 12 35 Any use installation maintenanc...

Reviews: