9.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
General data
Materials, wetted parts
Ʋ Transducer
PVDF
Ʋ Seal transducer/process fitting
EPDM, FKM
Ʋ Process fitting G1½, DIN 3852-A-B
PVDF
Ʋ Process fitting 1½ NPT,
ASME B1.20.1
PVDF
Materials, non-wetted parts
Ʋ Housing
Aluminium die-casting powder coated
Ʋ Seal, housing lid
Silicone SI 850 R (standard), NBR silicone-free (option)
Ʋ Inspection window in housing cover
Glass
Ʋ Ground terminal
316Ti/316L
Ʋ Cable gland
PA, stainless steel, brass
Ʋ Sealing, cable gland
NBR
Ʋ Blind plug, cable gland
PA
Weight
1.8 … 4 kg (4 … 8.8 lbs), depending on the process
fitting and housing
Max. torque mounting boss
25 Nm
Input variable
Measured variable
distance between lower edge of the transducer and
medium surface
Measuring range
Ʋ Liquids
up to 5 m (16.4 ft)
Ʋ Bulk solids
up to 2 m (6.562 ft)
blocking distance
0.25 m (0.82 ft)
Output variable
Output signal
4 … 20 mA/HART (active)
HART output values
Ʋ HART value (Primary Value)
Distance to the level
Ʋ HART value (Secondary Value)
Temperature
Ʋ HART value (3rd Value)
Distance to the level - scaled
Resolution
1.6 µA
Summary of Contents for OPTISOUND 3010 C
Page 1: ...OPTISOUND 3010 C Handbook Ultrasonic Level Transmitter Four wire 4 20 mA HART...
Page 49: ...49 Notes OPTISOUND 3010 C Four wire 4 20 mA HART 30504 EN 220310...
Page 50: ...50 Notes OPTISOUND 3010 C Four wire 4 20 mA HART 30504 EN 220310...
Page 51: ...51 Notes OPTISOUND 3010 C Four wire 4 20 mA HART 30504 EN 220310...