ELECTRICAL CONNECTIONS
4
21
OPTISENS TUR 2000
www.krohne.com
07/2017 - 4001970202 - MA OPTISENS TUR 2000 R01 en
The following instructions describe the connection of the sensor cable.
Connecting the sensor cable to the signal converter
•
Remove the terminal cover.
•
Thread the sensor cable through the middle right cable gland
1
.
•
Push the wires
7
into terminal J
3
, Q
4
, Y
5
, V
6
and S
2
.
•
To remove a wire, press down the white clip
8
on the corresponding terminal and pull the
wire out.